Spares and service. 

 

For advice or to arrange a commissioning / service visit, or if spare parts are required, please call our 

service/repairs department on 08707707747. 
 

Please ask for details on our routine maintenance scheme to ensure that your equipment is 
maintained in first class condition. 
 
Always quote the serial number in any communications regarding this unit, as we keep individual 
records of all units supplied. 
 
 

                 

  

 

 

General data

 

                 

EP1

                EP1HP             EP2                 EP2HP  

 
                                                                            

FACTORY SETTINGS 

 

 

Duty pump cut-in pressure                      2.5 BAR  

6 BAR              2.5 BAR  

  6 BAR 

 
Standby pump cut-in pressure                    N/A                  N/A               2.3 BAR 

5.8 BAR  

 

         

SE vessel pre-charge pressure                 2.3 BAR        5.8 BAR                2.3 BAR 

5.8 BAR 

 
Low pressure alarm cut-in pressure 

 .75 BAR 

3 BAR             0.75 BAR  

   3 BAR 

 
High pressure alarm cut-in pressure 

 3.0 BAR        6.5 BAR                   3.0 BAR 

6.5 BAR 

 
Pressure Regulating Valve                       1.5 BAR 

5 BAR                1.5 BAR 

   5 BAR  

 

 
Motor full load current (AMPS)        

   2.2A   

3.41A   

  2.2A   

   3.41A 

 
Power supply requirements 

 

240/1/50 240/1/50 240/1/50 240/1/50 

 

 

 

 

 

fused 13A 

fused 13A 

fused 13A 

fused 13A

 

 
 

 
 
 
  
 

  

 
 
 
 
 
 
 

 
 

 

Summary of Contents for ECONOPRESS EP 1

Page 1: ...G UNITS INCLUDING H P UNITS OPERATING AND MAINTENANCE INSTRUCTIONS STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL 08707 707 747 FAX 08707 707 767 E MAIL info stokvisboilers com...

Page 2: ...2 Contents Contents 2 General Description 3 Storage 4 Installation 4 Unit 5 Commissioning 5 Maintenance 7 Spare and service 8 General data Error Bookmark not defined...

Page 3: ...ressure the standby pump EP 2 units will start as the pressure falls further If the pressure within the system goes beyond preset design limits then the system pressure alarm switches will become acti...

Page 4: ...ther on a smooth level surface or alternatively back fixed to a suitable wall or other vertical structure in areas which are dry well ventilated and free from any danger from frost Once the unit has b...

Page 5: ...ctions Any parts removed for transit must be refitted The above in conjunction with the drawings should enable the unit to be installed ready for commissioning however if you require advice or assista...

Page 6: ...al switch on at low pressure the standby pump will run to cut out pressure and stop whereupon the duty pump will start and run to its cut out pressure On falling pressure the duty pump will start at i...

Page 7: ...p as indicated by the unit gauge Check that the switch resets before cold fill pressure is reached Close the valve between the unit and system and expansion vessels Run the pump raising the pressure a...

Page 8: ...records of all units supplied General data EP1 EP1HP EP2 EP2HP FACTORY SETTINGS Duty pump cut in pressure 2 5 BAR 6 BAR 2 5 BAR 6 BAR Standby pump cut in pressure N A N A 2 3 BAR 5 8 BAR SE vessel pre...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Reviews: