![Stoelting M202A Operator'S Manual Download Page 28](http://html1.mh-extra.com/html/stoelting/m202a/m202a_operators-manual_1381565028.webp)
Automatic Expansion Valve for Lemon Ice:
Original Factory Setting 40 PSIG
Typical pressure settings for Lemon Ice: 40 PSIG
Your final valve setting for Custard________
Your Final valve setting for Lemon Ice__________
Note: each machine will differ slightly in preferred setting.
Condensing Unit Settings: Air Cooled Units
(Location on each condensing unit)
Danfoss Head Pressure Control: Adjustable at 255 PSIG
High Pressure Safety Cut-Out: Non Adjustable at Approx. 350 PSIG
Low Pressure Safety Cut-Out:
Cut-In 20 PSIG
Cut-Out 0 PSIG
Fan Cycling Controls: Non Adjustable at 180 PSIG
Crankcase
Pressure
Regulator