background image

16

D. MONTHLY

CAUTION

THE FREEZER HAS AN AIR COOLED CON-
DENSER AND MUST HAVE PROPER AIR CIRCU-
LATION. DO NOT PLACE RIGHT SIDE OF
FREEZER ANY CLOSER THAN 3 INCHES FROM
THE WALL. FAILURE TO CLEAN THE CON-
DENSER FILTER ON A REGULAR BASIS MAY
RESULT IN SERIOUS FREEZER DAMAGE AND
COULD VOID FREEZER WARRANTY.

1.

Remove the phillips head screws from the lower side
of the right side panel and pull the side panel down and
out.

2.

Remove the condenser filter and clean in warm soapy
water. Rinse in clean water and squeeze dry, taking
care not to damage the filter in any way.

3.

Replace the condenser filter and side panel.

E. SEMI-ANNUALLY

1.

Check drive belt for proper tension. Push belt in with
one finger, belt should deflect about 3/8".

2.

Lubricate condenser fan motor with S.A.E. 20 weight
oil. Three to six drops is required.

CAUTION

DO NOT OVER LUBRICATE; RESULTING DAM-
AGE COULD CAUSE MOTOR FAILURE.

3.14 EXTENDED STORAGE

Refer to the following steps for storage of the freezer over
any long period of shutdown time:

A. Turn the OFF-ON switch to the OFF position.

B. Disconnect (unplug) from the electrical supply source.

C. Clean thoroughly with a warm detergent all parts that

come in contact with the mix. Rinse in clean water and
dry parts. Do not sanitize.

NOTE

Do not

 let the cleaning solution stand in the hopper

or in the freezer barrel during the shutdown period.

D. Remove, disassemble and clean the front door, mix

inlet regulator and auger parts. Place the auger flights
and the front auger support bushing in a plastic bag
with a moist paper towel to prevent them from becom-
ing brittle.

Summary of Contents for 513588R1

Page 1: ...OPTIMA 111 OWNER S MANUAL Manual No 513588R1 Nov 2004...

Page 2: ......

Page 3: ...are certified in the Stoelting Technicare program Model No _______________________ Serial No _______________________ Purchase Date ____________________ Start Up Date ____________________ CALL Distrib...

Page 4: ......

Page 5: ...tions and specifications are not binding in detail We reserve the right to make changes to the freezer without notice and without incurring any obligation to modify or provide new parts for freezers b...

Page 6: ......

Page 7: ...tor s Safety Precautions 7 3 2 Operating Controls and Indicators 7 3 3 Sanitizing 8 3 4 Freeze Down and Operation 9 3 5 MixInformation 10 3 6 Removing Mix From Freezer 10 3 7 Cleaning The Freezer 11 3...

Page 8: ...11 Mix Inlet Regulator 9 12 CleanControl 9 13 SanitizingHopper 9 14 DrainingSolution 9 15 DispensingProduct 10 16 RemovingMixInletRegulator 10 17 DrainingMix 10 18 Auger Flight Wear Front Auger Suppo...

Page 9: ...to operate with almost any type of commercial soft serve or non dairy mixer available including ice milk ice cream yogurt and frozen dietary desserts This manual is designed to assist qualified servi...

Page 10: ...6 kg Crated 400 lbs 181 4 kg ELECTRICAL Description O111 Voltage AC 1 PH 208 230 Total Run Amps 12 70 Drive Motor 2 HP Use 20 amp HACR circuit breaker Automatic safeguard circuit built into electroni...

Page 11: ...life of the freezer Labels should be checked periodi cally to be sure they can be recognized as warning labels If danger warning or caution labels are needed indicate the part number type of label loc...

Page 12: ...he freezer at each corner to check for level condition If adjustment is necessary levelthefreezerbyturningthebottompartofeachleg in or out Then separate freezer base gasket and installwithseamtothebac...

Page 13: ...i tion NOTE Detailed instructions are included with each floor stand B Place a spirit level across the top of the stand to check for level condition side to side and front to back If adjustment is nec...

Page 14: ...6...

Page 15: ...urs 3 2OPERATINGCONTROLSANDINDICATORS Before operating the freezer it is required that the operator know the function of each operating control Refer to Figure 10 for the location of the operating con...

Page 16: ...X LOW LENS TheredMIXLOWlightisdesignedtoalerttheoperator to a low mix condition The lens will illuminate with approximately one gallon of mix in the hopper When the MIX LOW lens is lit refill hopper i...

Page 17: ...ANDOPERATION This section covers the recommended operating proce dures to be followed for the safe operation of the freezer A Sanitize just prior to use B Place the OFF ON switch in the OFF position C...

Page 18: ...uid mix Fig 17 D Place the OFF ON switch in the OFF position Figure 17 Draining Mix CAUTION REFRIGERATION IS AUTOMATICALLY ACTI VATED WHEN THE SPIGOT IS OPENED CLOSE THE SPIGOT COMPLETELY AFTER DISPEN...

Page 19: ...FF POSITION BEFORE DISASSEMBLING FOR CLEANING OR SERVICING Inspection for worn or broken parts should be made at every disassembly of the freezer for cleaning or other purposes All worn or broken part...

Page 20: ...arts refertothefollowingsteps NOTE Petro Gel sanitary lubricant or equivalent must be used when lubrication of parts is specified NOTE The United States Department of Agriculture and the Food and Drug...

Page 21: ...rel F Installtheremainingplasticflights pushtheaugerinto the freezer barrel and rotate slowly until the auger engagesthedriveshaft G Install the bushing and auger support into the front of the auger w...

Page 22: ...solution for an extended period of time more about delimers in Additional Information 3 13PREVENTIVEMAINTENANCE It is recommended that a maintenance schedule be fol lowed to keep the freezer clean and...

Page 23: ...ll become a problem if not remedied with additional products and procedures THE USE OF CHLORINE TEST STRIPS Test strips are used to determine concentrations of active chlorine in sanitizing solutions...

Page 24: ...one finger belt should deflect about 3 8 2 Lubricate condenser fan motor with S A E 20 weight oil Three to six drops is required CAUTION DO NOT OVER LUBRICATE RESULTING DAM AGE COULD CAUSE MOTOR FAIL...

Page 25: ...N 1 e r u l i a f t l e b e v i r D 2 e r u t a r e p m e t y c n e t s i s n o C 3 m r i f o o t s i g n i t t e s e r u t a r e p m e t y c n e t s i s n o C 4 e r u l i a f l o r t n o c x i m l i...

Page 26: ...i r d n r o W 1 n r u t t o n l l i w r e g u A p u e z e e r F 2 e c i v r e s r o f r o t u b i r t s i d l l a C 1 5 1 r o f F F O o t h c t i w s N O F F O n r u T 2 t r a t s e r n e h t s e t u...

Page 27: ...of five Sequence of six Sequence of seven Program board Power board Low torque error Clean error Barrel sensor Hopper sensor Drive motor ERROR CODE SYSTEM Refer to Page 17 for Troubleshooting NOTE Fl...

Page 28: ...20...

Page 29: ...diameter 208381 Brush 95cm 3 8 diameter 208467 Brush 80cm 5 16 diameter 324107 Decal Hazardous Moving Parts 324105 Decal Electrical Shock Hazard 324106 Decal Applicable Electrical Code 324108 Decal C...

Page 30: ...22 U 17 4...

Page 31: ...t Rosette 8 3170644 1 Front Auger Support 9 149003 1 Bearing Front Auger Celecon 10 3156795 1 Auger 11 381804 5 Flight Loose Plastic Auger 12 694255 5 Spring Comp 13 624678 1 O Ring 1 1 2 x 1 1 8 x 3...

Page 32: ...24...

Page 33: ...Capillary Tube Drier Replacement 5 762448 1 Valve Expansion 1 2 Ton 6 762978 1 EPR Valve Green Label 7 762277 1 Check Valve Magni Chek 8 282032 SV 1 Compressor 208 230 60 1PH 9 284071 1 Condenser 2 Ro...

Page 34: ...26...

Page 35: ...26 4177556 1 Evaporator Weldment Foamed 27 M940077 As Reqd Epoxy Adhesive DP 110 Gray 3M 28 614232 1 Speed Reducer 5 2 1 Reduction 29 644605 4 Screw Cap 3 8 16 x 2 Hx Hd Zp Item Stoelting P N Qty Desc...

Page 36: ...28...

Page 37: ...brane Switch Black 31 649076 4 Screw Tap 8 32 x 3 8 Pan Hd Ph 32 766940 4 Washer Shakeproof 8 Zinc Plate 33 647393 5 Screw Mach 6 32 x 3 8 Rd Hd Ph Item Stoelting P N Qty Description 34 766933 8 Washe...

Page 38: ...30...

Page 39: ...Shock Hazard 21 324107 2 Decal Caution Hazardous Moving Parts 22 324208 1 Decal Attention Refrig Leak Check Item Stoelting P N Qty Description 23 324106 1 Decal Caution Wiring Mat l 24 M820309 As Req...

Page 40: ......

Page 41: ...ubject to the conditions that Buyer a signs and returns to Stoelting upon installation the Checklist Warranty Registration Card for the affected equipment b gives Stoelting prompt written notice of an...

Reviews: