Page 9
Due to continuous product research and development,
the information contained herein is subject to change without notice.
www.stoddart.com.au
www.stoddart.co.nz
Detergent Connection
Rinse Aid Connection
Detergent Installation and Adjustment
Rinse Aid Installation and Adjustment
• Isolate from power supply if connected
• Locate the correct hose/tube (Clear) on the rear of the unit
• Place the correct hose/tube into the detergent bottle
• Open the front panel by removing the two screws, then lifting the panel off carefully
• Locate the peristaltic detergent pump (left) and its adjustment screw
• To reduce the amount of detergent, screw the needle valve anticlockwise
• To increase the amount of detergent, screw the needle valve clockwise
• Isolate from power supply if connected
• Locate the correct hose/tube (Blue) on the rear of the unit
• Place the correct hose/tube into the Rinse Aid bottle
• Open the front panel by removing the two screws, then lifting the panel off carefully
• Locate the rinse aid pump (right) and its adjustment screw
• To reduce the amount of rinse aid, screw the needle valve anticlockwise
• To increase the amount of rinse aid, screw the needle valve clockwise
IMPORTANT
NEVER USE CHLORINE OR HYPOCHLORITE BASED
DETERGENTS!
FAILURE TO FOLLOW WILL VOID WARRANTY.
Installation
Adjustment
Screw
Adjustment
Screw