background image

Notes on Safety

ID 441806.03

4

Commissioning Instructions Bottom brake resistor

1

WE KEEP THINGS MOVING

Tab. 1-1: examples of occupational qualifications

In addition, the valid regulations, the legal requirements, the reference books, this technical documentation 
and, in particular, the safety information contained therein must be carefully

read

understood and

complied with

1.4

Installation and connection

Installation and connection work are only permitted after the device has been isolated from the power!
The accessory installation instructions allow the following actions during the installation of accessories:

The housing in the upper slot can be opened

The housing in the bottom slot can be opened.

Opening the housing in another place or for other purposes is not permitted.
The accessory installation instructions allow the following actions during the installation of accessories:

The housing in the upper slot can be opened.

Opening the housing in another place or for other purposes is not permitted.

Use only copper lines. For the line cross sections to be used, refer to DIN VDE 0298-4 or DIN EN 60204-1 
Appendix D and Appendix G.
Protect the device from falling parts (pieces of wire, leads, metal parts, and so on) during installation or other 
tasks in the switching cabinet. Parts with conductive properties inside the inverter can cause short circuits or 
device failure.
The motor must have an integrated temperature monitor with basic isolation in acc. with EN 61800-5-1 or 
external motor overload protection must be used.
The permissible protection class is protective ground. Operation is not permitted unless the protective 
conductor is connected in accordance with the regulations. 
Comply with the applicable instructions for installation and commissioning of motor and brakes.

Commissioning 

 

(of a standard application)

- Technician (m/f) (electro-technology)
- Master electro technician (m/f)

Programming

Graduate engineer (electro-technology or 
electrical power technology)

Operation

- Technician (m/f) (electro-technology)
- Master electro technician (m/f)

Disposal

Electronics technician (m/f)

Activity

Possible occupational qualifications

Summary of Contents for RB 5022

Page 1: ...Bottom brake resistor Commissioning Instructions Technical data Installation V 5 6 E or later 04 2012 en ...

Page 2: ...he product 3 1 2 Operation in accordance with its intended use 3 1 3 Qualified personnel 3 1 4 Installation and connection 4 1 5 Commissioning operation and service 5 1 6 Disposal 5 1 7 Presentation of notes on safety 6 2 Technical data 7 3 Assignment 8 3 1 MDS 5xxx 8 3 2 MDS 5xxxA 8 3 3 FDS 5xxx 9 3 4 FDS 5xxxA 9 3 5 SDS 5xxx 10 3 6 SDS 5xxxA 10 4 Installation 11 ...

Page 3: ... the device until the machine is disposed of If the product is sold disposed of or rented out always include the technical documentation with the product 1 2 Operation in accordance with its intended use The BR 5000 chassis brake resistors are only suitable for use on the POSIDRIVE MDS 5000 POSIDRIVE FDS 5000 and POSIDYN SDS 5000 inverters Unintended use includes use on other devices 1 3 Qualified...

Page 4: ... place or for other purposes is not permitted Use only copper lines For the line cross sections to be used refer to DIN VDE 0298 4 or DIN EN 60204 1 Appendix D and Appendix G Protect the device from falling parts pieces of wire leads metal parts and so on during installation or other tasks in the switching cabinet Parts with conductive properties inside the inverter can cause short circuits or dev...

Page 5: ...es Before carrying out any work on the machine observe all the following five safety regulations in the above mentioned sequence 1 Enable Ensure that you also activate the auxiliary circuits 2 Secure against switching on 3 Ensure that the parts are de energized 4 Earth and short circuit 5 Cover or isolate any live neighboring parts You can then start your work on the drive controller Repairs may o...

Page 6: ...ning triangle means that minor injury may occur X if the stated precautionary measures are not taken WARNING Warning means that there may be a serious danger of death X if the stated precautionary measures are not taken DANGER Danger means that serious danger of death exists X if the stated precautionary measures are not taken Information indicates important information about the product or a high...

Page 7: ... 4 Type RB 5022 100 W 22 Ω RB 5047 60 W 47 Ω RB 5100 60 W 100 Ω RB 5200 40 W 200 Ω Height x width x depth mm 300 x 94 x 18 300 x 62 x 18 Drilling template corresponds to size Size 2 Size 1 Size 0 and 1 Size 0 Thermal time constant τ s 8 6 Weight g approx 640 approx 460 approx 440 Length of cable mm 250 Maximum torque for studs Nm 5 Protection Rating IP 40 ...

Page 8: ...022 100 W 22 Ω RB 5047 60 W 47 Ω RB 5100 60 W 100 Ω RB 5200 40 W 200 Ω ID no 45618 44966 44965 44964 MDS 5007 X X MDS 5008 X MDS 5015 X MDS 5040 X MDS 5075 X MDS 5110 X MDS 5150 X Type RB 5022 100 W 22 Ω RB 5047 60 W 47 Ω RB 5100 60 W 100 Ω ID no 45618 44966 44965 MDS 5007A X MDS 5008A X MDS 5015A X MDS 5040A X X MDS 5075A X MDS 5110A X MDS 5150A X ...

Page 9: ...Ω RB 5100 60 W 100 Ω RB 5200 40 W 200 Ω ID no 44966 44965 44964 FDS 5007 X X FDS 5004 X FDS 5008 X FDS 5015 X FDS 5022 X FDS 5040 X FDS 5055 X X FDS 5075 X Type RB 5047 60 W 47 Ω RB 5100 60 W 100 Ω RB 5200 40 W 200 Ω ID no 44966 44965 44964 FDS 5007A X X FDS 5004A X X FDS 5008A X X FDS 5015A X X FDS 5022A X FDS 5040A X X FDS 5055A X X FDS 5075A X ...

Page 10: ...SDS 5xxxA Type RB 5022 100 W 22 Ω RB 5047 60 W 47 Ω RB 5100 60 W 100 Ω ID no 45618 44966 44965 SDS 5008 X SDS 5015 X SDS 5040 X SDS 5075 X SDS 5110 X SDS 5150 X Type RB 5022 100 W 22 Ω RB 5047 60 W 47 Ω RB 5100 60 W 100 Ω ID no 45618 44966 44965 SDS 5008A X SDS 5015A X SDS 5040A X X SDS 5075A X SDS 5110A X SDS 5150A X ...

Page 11: ...ter this Prerequisites You have bored the holes for threaded bolts as per chapter 2 Technical data in the switching cabinet where the inverter is to be installed The threaded bolts are included with the bottom brake resistor You will need the following for installation The threaded bolts included with the bottom brake resistor The screws and washers included with the bottom brake resistor A Philli...

Page 12: ...Bottom brake resistor 4 WE KEEP THINGS MOVING 2 Place the inverter on the guide rails 3 Press the inverter downwards on the guide rails 4 Secure the inverter to the threaded bolts with the screws and washers Ö You have now installed the bottom brake resistor ...

Page 13: ...7393 eMail info stoeber cn www stoeber cn STOBER DRIVES INC 1781 Downing Drive Maysville KY 41056 Fon 1 606 7595090 Fax 1 606 7595045 eMail sales stober com www stober com STOBER DRIVES LTD Upper Keys Business Village Keys Park Road Hednesford Cannock WS12 2HA Fon 44 0 1543 458 858 Fax 44 0 1543 448 688 E Mail mail stober co uk www stober co uk STOBER Japan P O Box 113 002 6 chome 15 8 Hon komagom...

Page 14: ...ner Str 12 75177 PFORZHEIM GERMANY Tel 49 0 7231 582 0 Fax 49 7231 582 1000 E Mail mail stoeber de www stober com 24 h service hotline 49 0 180 5 786 323 Technische Änderungen vorbehalten Errors and changes excepted ID 441806 03 04 2012 441806 03 ...

Reviews: