background image

Electrical Supply

Installation must be carried out by a qualified electrician in 

accordance with BS 7671:2008 Wiring Regulations.

230/240V AC 50/60Hz mains supply to a suitable SELV 

LED Driver.

Site conditions: LED equipment is more susceptible to 

static damage and overvoltage than previous technology. 

Before handling or connecting to the mains supply ensure 

that all MSL products are protected from static discharge 

and that the mains supply is to regulation. (230V +10 

-6%)

This fitting is supplied with a Xicato LED module.  Refer 

to the fitting label for the module version and wattage.  

More information on the module can be found at 

www.xicato.com/support

Mains cables must be double insulated, strain relieved 

and separated from E.L.V output cables.

This unit requires a constant current driver.  700mA Max. 

Observe polarity:

Positive (+) is marked as RED.

Incorrect supply or reverse polarity can cause irreparable 

damage.

All connections must be made before switching on mains.  

If the supply is energised prior to making the connections 

to the fitting then the resulting surge will damage the LED.

All lighting equipment is delicate and easily damaged 

through misuse or inappropriate installation (mechanical 

or electrical). Repairs and replacements may cause 

delays and will be chargeable. Contact MSL for support if 

required.  For full warranty terms & conditions please visit 

our website.

Dimming control circuit source must be of SELV insulation 

class.   

Ensure supply driver and connectors are housed indoors 

OR in a suitably IP rated enclosure.

Installation

Check that the mounting surface is suitable for the 

installation of this fitting. 

An 86mm diameter hole is required for mounting.

Step 1  Make mains connections to SELV LED driver  

and extra low voltage connections to the  

 fitting. 

Step 2  Insert the fitting into the cutout and secure in  

place with silicone or similar.

After opening the sealed portion of the luminaire for 

any reason, MSL recommends running the fitting for 

15 minutes with the lid open to expel moisture before 

closing it up.  This will prevent condensation on the 

lens and protect the fitting from corrosion.

WARNING: Do not look at exposed LED lamps in 

operation. Eye injury can result.

Cleaning:      

Fully isolate the fitting and allow to cool.

Clean the fitting with a damp lint free cloth and a mild 

solution of soap and water.  The fitting must be 

completely dry before reconnecting power.

Incompatible or abrasive chemicals can damage the 

fitting, contact MSL for advice if required.