18
AFTER SALES SUPPORT
1300 886 649
AUS
MODEL: STR-GH PRODUCT CODE: 49187 05/2015
Final installation checks
After commissioning and before leaving, the installer must check and ensure
that:
• There are no leaks in the gas supply, using a soap and water solution.
• All parts (burners, enamelled trivets, knobs) and the gas pipe are installed
correctly.
• The ignition system is working satisfactorily on all burners, both individually
and combined.
• When lit, each burner produces a well defined blue flame without any
yellow tipping.
• Each burner flame remains lit when the respective control knob is rotated
quickly from the
Maximum
to the
Minimum
aperture
position.
• A duplicate data label is provided with this appliance. Please attach this
label to an accessible and nearby surface for easy reference.
Commissioning process
The below process must be performed on the gas cooktop by the authorised
installer before leaving:
• The supplied gas regulator is a “non-adjustable” type, to check operation,
turn on and light the Rapid Burner only.
• Measure and confirm the Test Point pressure is 1KPa.
Installation (Cont.)