Table 1: General injectors
Type of Gas
Nozzle mm
Burner
Power (MJ/)
Max.
Min.
Natural Gas
(NG)
1.49
Rapid
10.8
5.4
1.16
Semirapid
6.5
3.24
0.85
Auxiliary
3.6
1.8
LPG
Butane
Propane
0.93
Rapid
11
5.4
0.72
Semirapid
6.6
3.24
0.53
Auxiliary
3.7
1.8
Installation (Cont.)
• Reassemble all the burners carefully; in particular you should make sure
that the burner crown is correctly placed on the burner.
•
IMPORTANT:
The minimum flow adjustment process must be completed
before the appliance is next used.
Minimum flow adjustment for hob gas taps
IMPORTANT:
Before adjusting the minimum flow of the burners, make
sure all gas is switched off (and preferably disconnected from the
appliance) and the electrical power has been disconnected.
• Remove all the trivets, burner crowns and
caps, and knobs.
• Unscrew the screws of the panel, then
remove the panel.
• Install the burner cap, burner crown and
knob of the burner. Switch the burner on
and set the knob at the minimum position.
• Place a small-bladed screwdriver on the
screw to adjust the minimum flow (as
shown in Fig. 11).
• Unscrew the adjusting screw in order to
increase the gas flow, or tighten it in order
to decrease the gas flow.
• The correct adjustment is obtained when
the flame has a length of about 3–4 mm.