Checks and actions prior to commissioning
Checking the emergency shutdown
To check the operation of the emergency off
switch, proceed as follows:
–
Start up the truck.
–
Drive the truck.
–
Press the emergency off switch (1).
●
The truck stops immediately.
●
The truck power supply is cut.
●
The electrical controls and motors are no
longer supplied with power.
–
Pull the emergency off switch (1).
The functions are available again.
NOTE
Ensure that the stabiliser wheels operate cor-
rectly. This influences braking effectiveness.
Checking the brakes
To check the main brakes of the truck, pro-
ceed as follows:
–
Press the braking button (1).
The truck comes to a standstill.