In the event of leakage, please contact the Af-
ter-Sales Service Centre.
Checking the oil level in the control-
led stabiliser circuit
–
Switch off the truck and disconnect the bat-
tery connector.
–
Remove the hood of the technical compart-
ment.
It is essential that the oil level of the stabilisers
is on the mark situated between the raised
MIN and MAX (3) lettering on the tank (2)
–
Top up the level if necessary, after un-
screwing the plug (1).
–
Screw the plug back in at the end of the op-
eration.
CAUTION
Risk of damage to the truck
Only use hydraulic oil that complies with the specifi-
cations. See table of lubricants.
–
Refit the hood of the technical compart-
ment.
–
Return the truck to service.
Maintenance
5
Hydraulic systems
115
11638011751 EN - 02/2021 - 03
Summary of Contents for EXD-S 20
Page 1: ...Double pallet stacker EXD S 20 Original instructions 0347 11638011751 EN 02 2021 03 ...
Page 2: ......
Page 4: ......
Page 10: ......
Page 11: ...1 Introduction ...
Page 20: ...Introduction 1 Disposing of components and batteries 10 11638011751 EN 02 2021 03 ...
Page 21: ...2 Safety ...
Page 31: ...3 Overviews ...
Page 40: ...Overviews 3 Markings 30 11638011751 EN 02 2021 03 ...
Page 41: ...4 Use ...
Page 105: ...5 Maintenance ...
Page 130: ...Maintenance 5 Storage and decommissioning 120 11638011751 EN 02 2021 03 ...
Page 131: ...6 Technical specifications ...
Page 138: ...Technical specifications 6 EXD20 S mast type 128 11638011751 EN 02 2021 03 ...
Page 142: ......
Page 143: ......