Indicator light
The charging indicator (1)displays the follow-
ing different states:
Charging indicator
Display
Description
Malfunction analysis
Red light remains lit
Charger is charging
Normal status
Power display light (2)normal status display:
Name
LED colour
Parameter value
Remaining charge on standard
battery
Green
60-100%
Yellow
30%-60%
Constantly illuminated in red
15-30%
Flashing red
0-15%
If the control unit detects a battery malfunc-
tion, the power display light (2)will flash with
an error code until the malfunction is elimina-
ted.
NOTE
Please see the chapter "Troubleshooting" ,
This chapter is intended to help users identify
and eliminate simple faults or problems
caused by operational errors.
Views
3
Indicator light
40
5001 801 1532 EN - 10/2021 - 03