2.0 Facility Preparation
Prior to uncrating your machine confirm that your location can
accommodate the Ironwood CUT 18. Follow these guidelines:
2.1 Floor
• The floor must be flat and level.
• Although no special foundations are required, a concrete floor is
recommended.
• All floors must have a load-bearing strength suitable for the
machine weight of approximately 800 pounds.
• The machine need not be anchored to the floor. However, if you
decide to do so, purchase high quality anchor bolts appropriate
to the floor construction and material.
2.2 Work Space
• Provide adequate work space surrounding the machine.
• Provide proper non-glare, overhead lighting to keep the work
space well lit.
• Place the machine so that any potential kickback area is not in
line with aisles, doorways, or other work and traffic areas.
• Provide an adequate dust extraction system. The dust extraction
system should have a flow rate of 4500 feet/min at 450 cfm.
• Avoid exposure to any environment where vibration is present.
• Avoid exposure to direct sunlight or heat.
1'-6"*
(500mm)
(work area)
1'-6"
(500mm)
(work area)
2'-0"
(600mm)
(work area)
7'-6"
(2300mm)
(work area)
1'-6"*
(500mm)
(work area)
6'-6"
(2000mm)
(work area)
Machine clearance requirements*
*Actual clearance requirements may vary depending on length of
material to be cut.
2.3 Power
WaRninG
A licensed electrician must connect the CUT 18 to the building
power source.
• Do not use extension cords.
• Be sure that the electrical current of the power source is of the
same characteristics as the electrical system supplied with your
machine. If other machine voltage capabilities are required,
contact Stiles Machinery.
• Provide access to a suitable power source.
CUT 18
Motor
10 HP
Motor Power
230v (3 phase) /
460v (3 phase)
Amperage
25 amps (230v) /
12.5 amps (460v)
• Ensure the machine is protected with an external over-current
protective device per your local electrical codes.
• Electrical equipment operating conditions:
Air temperatures b41ºF (+5ºC) and +113ºF (+45ºC).
Relative humidity not to exceed 50% at a maximum temperature
of +113ºF (+45ºC).
• Electrical equipment is designed and protected to withstand the
effects of transportation and storage temperatures within a range
of -13ºF (-25ºC) to +131ºF (+55ºC), and for short periods of time
not exceeding 24 hours at up to +158ºF (+70ºC).
• Ensure connection to factory ground system is wired correctly
(according to IAW local electrical codes and National Electric
Code) and not connected to any electromagnetic interference
source such as welders.