KA 85 R
English
41
During break-in period
A factory-new machine should not be
run at high revs (full throttle off load) for
the first three tank fillings. This avoids
unnecessary high loads during the
break-in period. As all moving parts
have to bed in during the break-in
period, the frictional resistances in the
engine are greater during this period.
The engine develops its maximum
power after about 5 to 15 tank fillings.
During Operation
After a long period of full throttle
operation, allow the engine to run for a
short while at idle speed so that engine
heat can be dissipated by the flow of
cooling air. This protects engine-
mounted components (ignition,
carburetor) from thermal overload.
After Finishing Work
Storing for a short period: Wait for the
engine to cool down. Empty the fuel tank
and keep the machine in a dry place,
well away from sources of ignition, until
you need it again. For longer out-of-
service periods – see "Storing the
Machine".
Dirty air filters reduce engine power,
increase fuel consumption and make
starting more difficult.
Your power tool comes standard with
either a clip-on or screw-mounted filter
cover.
If there is a noticeable loss of engine
power
N
Set the choke lever to
g
.
On the clip-on filter cover:
N
Press in the tab (1) and swing the
filter cover (2) away.
On the screw-mounted filter cover:
N
Loosen the screw (3) and remove
the filter cover (2).
On both versions:
N
Clean away loose dirt from around
the filter.
N
Remove the foam and felt filter
elements.
N
Wash the foam element in a clean,
non-flammable solution (e.g. warm
soapy water) and then dry.
N
Fit a new felt element – do not wash.
As a temporary measure you can
knock it out on the palm of your
hand or blow it out with compressed
air.
Replace any damaged parts.
Operating Instructions
Cleaning the Air Filter
355BA014 KN
2
1
3
392BA046 KN
2