Troubleshooting
Always remove the battery before carrying out any work on the power tool.
Condition
Cause
Remedy
Machine does not run when switched on
No electrical contact between power tool
and battery
Remove battery, check contacts and refit
battery
Battery discharged
(1 light emitting diode on battery flashes
green)
Charge the battery
Battery too hot / too cold
(1 light emitting diode on battery lights
up red)
Allow the battery to cool down / Warm up
the battery slowly at a temperature
between 15°C and 20°C.
Battery faulty
(4 light emitting diodes on battery flash
red)
Install new battery
1)
Power tool too warm
(3 light emitting diodes on battery light
up red)
Allow power tool to cool down
Power tool faulty
(3 light emitting diodes on battery flash
red)
Have power tool checked by servicing
dealer
1)
Moisture in power tool and/or battery
Allow power tool/battery to dry
Power tool cuts out during operation
Battery or power tool circuitry too warm Take the battery out of the power tool;
allow the battery and power tool to cool
down
Electrical malfunction
Remove the battery and refit it properly