PRECAUTIONS 

The VIGIRO

® 

IP26 should be installed and connected exclusively by competent personnel. The personnel need to have 

electrical accreditation, a knowledge of the regulation and the disposition concerning the installation of those device, 

especially for Ex II3D version integrated in ATEX zones.  

    Perform before head a study of electrical connection to instal the VIGIRO

® 

IP26 (standardized electrical diagram, electrical 

power and protection, autopilot, ATEX zones). 
    Define the under-speed threshold to apply for the security of the bucket elevator or the belt conveyor to avoid any risk of 
overheating (ex: Engine stopping under-speed threshold defined at 6% between the speed observed on the driven pulley and 

the nominal speed of the driving pulley). 

Control that the operating temperature range of the VIGIRO IP26

® 

(variable depending on version) corresponding at 

your application. 

Verify during the first commissioning of the bucket elevator, in handling stage, that the VIGIRO IP26

® 

stay still and 

maintained by its antirotating strap (only the VIGIRO IP26

® 

shaft should be rotating). 

Shut down the bucket elevator or the belt conveyor (de-energized) before any intervention on VIGIRO IP26

® 

(intervention information to be indicated on the machine) 
 

Optional                           (magnetic fixation without tapping) : 
The 

EAZY-FIX 

can’t be installed on a stainless

-steel shaft.  

Ensure that the bearing surface of the shaft is clean and plane. 

Take precaution during installation of the 

EAZY-FIX 

because its very strong  

magnetic force of attraction can cause pinching injury. 

CAUTION… The magnetic field of the 

EAZY-FIX may damage some sensitive 

system such as magnetic tracks or tapes, certain watc

hes, etc… 

 

 
 

INSTALLATION 

 

Assembly without EAZY-FIX 

Perform a M12 tapping (optional M10) at the end of the pulley shaft with a minimal depth of 18mm following drawing 
A (Be careful to center the tapping to avoid eccentricity effects in service). 

Coat the tapping with removable thread locker, then screw the VIGIRO

®

 IP26 on the pulley shaft with a 16mm open-end 

wrench. 
Make sure to respect the setting time of the thread lock before using it for the first time. 

Assembly with EAZY-FIX (optional) 

Coat the tapping with removable thread locker of the optional 

EAZY-FIX

, then screw the VIGIRO

®

 IP26 on the 

EAZY-FIX

 

with a 16mm open-end wrench. 
Make sure to respect the setting time of the thread lock before using it for the first time. 

 

Finish by fixing the anti-rotation strap without creating tension between the VIGIRO

®

 IP26 and the anchor point. 

 

(M12)

 

Drawing A 

18 

M

12

/M

10

 

Pulley shaft 

Thread lock 

Thread lock 