INSTRUCTION MANUAL
GB
–
2/3
- N° DOC BE0455060-A
PRECAUTIONS
The VIGIRO
®
IP26 should be installed and connected exclusively by competent personnel. The personnel need to have
electrical accreditation, a knowledge of the regulation and the disposition concerning the installation of those device,
especially for Ex II3D version integrated in ATEX zones.
Perform before head a study of electrical connection to instal the VIGIRO
®
IP26 (standardized electrical diagram, electrical
power and protection, autopilot, ATEX zones).
Define the under-speed threshold to apply for the security of the bucket elevator or the belt conveyor to avoid any risk of
overheating (ex: Engine stopping under-speed threshold defined at 6% between the speed observed on the driven pulley and
the nominal speed of the driving pulley).
Control that the operating temperature range of the VIGIRO IP26
®
(variable depending on version) corresponding at
your application.
Verify during the first commissioning of the bucket elevator, in handling stage, that the VIGIRO IP26
®
stay still and
maintained by its antirotating strap (only the VIGIRO IP26
®
shaft should be rotating).
Shut down the bucket elevator or the belt conveyor (de-energized) before any intervention on VIGIRO IP26
®
(intervention information to be indicated on the machine)
Optional (magnetic fixation without tapping) :
The
EAZY-FIX
can’t be installed on a stainless
-steel shaft.
Ensure that the bearing surface of the shaft is clean and plane.
Take precaution during installation of the
EAZY-FIX
because its very strong
magnetic force of attraction can cause pinching injury.
CAUTION… The magnetic field of the
EAZY-FIX may damage some sensitive
system such as magnetic tracks or tapes, certain watc
hes, etc…
INSTALLATION
Assembly without EAZY-FIX
Perform a M12 tapping (optional M10) at the end of the pulley shaft with a minimal depth of 18mm following drawing
A (Be careful to center the tapping to avoid eccentricity effects in service).
Coat the tapping with removable thread locker, then screw the VIGIRO
®
IP26 on the pulley shaft with a 16mm open-end
wrench.
Make sure to respect the setting time of the thread lock before using it for the first time.
Assembly with EAZY-FIX (optional)
Coat the tapping with removable thread locker of the optional
EAZY-FIX
, then screw the VIGIRO
®
IP26 on the
EAZY-FIX
with a 16mm open-end wrench.
Make sure to respect the setting time of the thread lock before using it for the first time.
Finish by fixing the anti-rotation strap without creating tension between the VIGIRO
®
IP26 and the anchor point.
(M12)
Drawing A
18
M
12
/M
10
Pulley shaft
Thread lock
Thread lock
Magnetic hold
at the end of the shaft