21
Note
If the device is switched on and still shows no function, the power supply may be
interrupted. Please check the fuse (6) and exchange it if needed (please see “Technical
Data”).
To reduce the pressure inside the unit it is necessary to turn off the unit on the ON/OFF
switch (5). Turn the pressure regulator knob CCW totally. Turn on the unit with the
ON/Off switch (5). Now you can adjust the fluid pressure independently by turning the
pressure regulator knob CW.
Important:
After bleeding the brake system with a lower or higher pressure than 2 bar, the
pressure regulator must be reset to 2 bar!
When does the unit needs to be refilled?
After reaching a low level of brake fluid inside the container, the unit will shut off the
motor + pump automatically. This will ensure that no air will reach the brake system at
all.
As an additional control feature an acoustic warning signal and control lamp (7) lights
up.
In this case, the empty brake fluid container must be exchanged for a full one. For this
the unit should be turned off on the ON/OFF switch (5). Please continue the procedure
according to the heading “Operation start-up”.
Disposal
The unit is to be returned to your sales partner or be disposed off in compliance with
the legal and official waste regulations.