Stierius VARIO 5 Operating Instructions Manual Download Page 4

17

Delivery Status / Installation / Operation start-up

The packing will contain the following parts at the delivery status:

1 Control Assy.

(incl. Pressure hose and Power cord)

1 Chassis
4 Mounting Screws
1 Suction tube assy.
1 Adapter no. 20
1 Recovery bottle

(only PRO)

Please check the unit after unpacking for any transportation damage.
Transport damages should be immediately reported to the responsable carrier!

Part

Part Description

Part

Part Description

1

Control assy. 

11

Suction tube assy.

2

Pressure hose

12

Sealing cone

3

Pressure hose coupler

13

Unmistakeable nipple for suktion tube

4

Power cord

14

Coupler for suktion tube

5

ON/OFF-Switch

15

Connection low fluid indicator

6

Fuse

16

Container security barr 

7

Low fluid level indicator

17

Wheel with cap

8

Self purging nipple

18

Caster cpl.

9

Pressure regulator 

EPC: /-

19

Adapter No. 20

10

Gauge

PRO-Version:

21

Spiral hose

23

Recovery bottle

22

Pipet

24

Recovery bottle hose

Corrective maintenance / Repair

Corrective maintenance and repair at the unit may only be performed by expert 
personal!

The device is designed so in case of any defect only the control  assy. must be sent in 
for inspection. 
In this case: 
The mounting screws on the left and right panel must be unscrewed. 
Take down the control assy. incl. filling hose and power cord from the chassis.

GB

Summary of Contents for VARIO 5

Page 1: ...Bedienungsanleitung Operating Instructions Mode d emploi Istruzioni per l uso Bremsen Service Ger te VARIO 5 VARIO 20 II VARIO 20 II PRO EG 30 60 EPC EG 30 60 EPC PRO...

Page 2: ...ure that the device is without current i e switched off and the power plug pulled and the brake fluid has been drained from the unit 6 Repairs may only be performed by trained professionals with corre...

Page 3: ...to fail It is recommended to use only brake fluid from its original container The hygroscopic properties of brake fluid cause it to draw and take in moisture from the air This dangerously reduces the...

Page 4: ...eable nipple for suktion tube 4 Power cord 14 Coupler for suktion tube 5 ON OFF Switch 15 Connection low fluid indicator 6 Fuse 16 Container security barr 7 Low fluid level indicator 17 Wheel with cap...

Page 5: ...m Electrical fuse M2 0A 5x20 mm Length of power cord ca 4 5 m Reg pressure range 0 3 5 bar adjustable Empty weight 23 kg Low fluid level shut off Yes Temp work area 0 C 45 C Pressure gage 0 6 bar 0 8...

Page 6: ...p This procedure should be performed before every bleed job When the unit is well purged turn the unit off 5 and remove the quick coupling 3 from the nipple 8 The unit is now ready to use 6 Connect th...

Page 7: ...the pressure regulator knob CW to the desired pressure Attention After changing the pressure adjustment of the bleeding unit readjust it back to the factory setting of 2 bar Feature Pre suction system...

Page 8: ...ssure than 2 bar the pressure regulator must be reset to 2 bar When does the unit needs to be refilled After reaching a low level of brake fluid inside the container the unit will shut off the motor p...

Page 9: ...properly with a wrench During bleeding process we recommend that the pedal be pressed a few times to flush the primary and secondary chambers of the master cylinder This flushes the dirt and air from...

Page 10: ...23 Accessories Recovery Bottle Part No 3 0070 Reverse Bleeder Hose No 67 Part No 3 0069 Various adapters Please take note to our adapter application list www stierius com GB...

Page 11: ...odo Stier Hydrotechnik GmbH Gutenbergstr 2 4 D 78727 Oberndorf Neckar Telefon 49 0 7423 3321 49 0 7423 4711 Technische Hotline Fax 49 0 7423 82422 Internet http www stierius com Email service stierius...