Operating Instructions:

1.

Place a new brake fluid container on the fluid can holding platform. Next secure the
hold down chain to prevent can from slipping (16).

2.

Remove the large container opening and place the fluid pick-up tube (11) into the
opening. Be sure to press the seal cone (12) against the opening of the container.

3.

Connect the quick coupler (3) of the pressure hose (2) to the self purging nipple (8).

4.

Plug the power cord (4) of the unit into the proper wall outlet. (230V AC, 0,1kW,
50Hz)

5.

To insure an air free bleed run the unit for at least 30 seconds with the quick
coupler (3) of the pressure hose  (2) connected to the self purge nipple (8). This 
purges the air from the hose and the pump. This procedure should be performed
before every bleed job. When the unit is well purged, turn the unit off (5) and 
remove the quick coupling (3) from the nipple (8). The unit is now ready to use.

6.

Connect the quick coupler (3) of the pressure hose (2) to a properly installed
master cylinder adapter.

7.

Turn the power switch (5) to the ON position. The green switch light should be
illuminated.

8.

Adjust the bleeding pressure by turning the pressure regulator knob (9) to the
recommended pressure by the vehicle manufacturer. The bleeding can now begin.
According to the vehicle manufactures procedure, bleed the system. These 
instructions are to be specifically followed when working on ABS systems.

9.

Before removing the pressure hose (2) from the master cylinder adapter, relieve
the pressure by switching the unit off (5). Return the original master cylinder cover
back onto the master cylinder reservoir.

GB

Summary of Contents for VARIO 5

Page 1: ...Bedienungsanleitung Operating Instructions Mode d emploi Istruzioni per l uso Bremsen Service Ger te VARIO 5 VARIO 20 II VARIO 20 II PRO EG 30 60 EPC EG 30 60 EPC PRO...

Page 2: ...ure that the device is without current i e switched off and the power plug pulled and the brake fluid has been drained from the unit 6 Repairs may only be performed by trained professionals with corre...

Page 3: ...to fail It is recommended to use only brake fluid from its original container The hygroscopic properties of brake fluid cause it to draw and take in moisture from the air This dangerously reduces the...

Page 4: ...eable nipple for suktion tube 4 Power cord 14 Coupler for suktion tube 5 ON OFF Switch 15 Connection low fluid indicator 6 Fuse 16 Container security barr 7 Low fluid level indicator 17 Wheel with cap...

Page 5: ...m Electrical fuse M2 0A 5x20 mm Length of power cord ca 4 5 m Reg pressure range 0 3 5 bar adjustable Empty weight 23 kg Low fluid level shut off Yes Temp work area 0 C 45 C Pressure gage 0 6 bar 0 8...

Page 6: ...p This procedure should be performed before every bleed job When the unit is well purged turn the unit off 5 and remove the quick coupling 3 from the nipple 8 The unit is now ready to use 6 Connect th...

Page 7: ...the pressure regulator knob CW to the desired pressure Attention After changing the pressure adjustment of the bleeding unit readjust it back to the factory setting of 2 bar Feature Pre suction system...

Page 8: ...ssure than 2 bar the pressure regulator must be reset to 2 bar When does the unit needs to be refilled After reaching a low level of brake fluid inside the container the unit will shut off the motor p...

Page 9: ...properly with a wrench During bleeding process we recommend that the pedal be pressed a few times to flush the primary and secondary chambers of the master cylinder This flushes the dirt and air from...

Page 10: ...23 Accessories Recovery Bottle Part No 3 0070 Reverse Bleeder Hose No 67 Part No 3 0069 Various adapters Please take note to our adapter application list www stierius com GB...

Page 11: ...odo Stier Hydrotechnik GmbH Gutenbergstr 2 4 D 78727 Oberndorf Neckar Telefon 49 0 7423 3321 49 0 7423 4711 Technische Hotline Fax 49 0 7423 82422 Internet http www stierius com Email service stierius...

Reviews: