STIENEN PL-9400 User Manual Download Page 36

 

Page 36 of 41 

INFO 

 

 

 

 

 

 

You can use the “Reset min/max 

temp.” setting to clear the min/max 

measurements in all temperature 

listings and to fill “Today” with the 

current value. 

 

The Temperature, Counters and 

Timers, feed system and animal 

weighing screens are identical to 

menu option “Overviews”. 

 

ANIMAL DATA 

 

 

 

 

TO MUTATE 

If there are more groups of animals, you can enter the following data per group of animals. Use the 

 and 

 

keys to select the next/previous group of animals. 

 

Lost 

You can set up to 5 different categories of lost (see “Configuration lost”) 

Dead 

Enter the number of animals which have lost at this moment (per group of animals). 

“Today's” mortality (or death rate) is increased automatically by the value entered after 

which the entry is erased. 

Dead “Today” 

Today's total mortality. If you have entered an incorrect value you can correct this by 

changing the value below “Today”. 

Dead “Total” 

"Total" shows the total mortality calculated using the mortality of the previous days and 

of “Today” 

Selection .. Lost 5 

See “Dead”. 

Out 

Enter the number of animals that has been removed. 

Out “Total” 

The “Total” number of animals removed. 

In 

Fill in the number of animals that were added. 

In “Total” 

The “Total” number of animals added. 

Animals present 

This is the sum of the number of animals at the time of entry – the total mortality - total 

out + total in. 

Number at entry 

This is the number of animals at the time of entry. 

 

Summary of Contents for PL-9400

Page 1: ...USER MANUAL PL 9400 i POULTRY COMPUTER EN StienenBE PL 9400 G EN02000 PL 9400 PL 9400 i...

Page 2: ...y questions Be sure to have all necessary data at hand To ensure a speedy solution to the malfunction and to avoid any misunderstandings it is advisable to note down the cause and the circumstances in...

Page 3: ...eous controls 16 Temperature controls 16 Temperature monitoring 17 Compensations climate control 17 Temperature overview 25 Alarm 25 Thermo differential alarm 26 HOUSE STATUS 27 In use 27 Not in use 2...

Page 4: ...utlet FSO push on the flap of the fixed socket outlet until you hear it click lock Alarm codes installation 39 SYSTEM 40 Display 40 MAINTENANCE AND CHECK UP 41 Appication notes Animal weighing PL9XIAW...

Page 5: ...ieve the remaining settings and or measurements using the cursor up and down keys KEYBOARD Caution Only press the keys with the tip of your finger Sharp objects such as a pen pencil or screwdriver may...

Page 6: ...or the next control if there are any controls of the same type such as ventilation groups left right recirculation etc Alarm key switching the main alarm on and off Hot key for alarm screen The LED in...

Page 7: ...text will automatically start with an initial capital 4 NAVIGATION KEYS MENU CURSOR MODE Cancel This key cancels changes or menu option selections Press and hold this key to select the main menu Move...

Page 8: ...tput is indicated by a letter in accordance with the table below The serial number must be between 01 and 99 00 means that the input output is not used Type in output Letter Serial number Description...

Page 9: ...he Overview window After selecting this window you will have to enter the access code again to be able to change a setting ACCESS CODE You can use an access code to protect your computer against unaut...

Page 10: ...r higher than 10 0 C is set this will be an absolute temperature setting Manure belt Heater block Always relative to temperature in the house n a Ventilation groups Always relative to temperature in t...

Page 11: ...ouse also see Automatic bandwidth compensation on page 18 MINIMUM AND MAXIMUM VENTILATION If compensation depending on the fill ratio has been installed the minimum and or maximum ventilation will be...

Page 12: ...not be displayed Minimum flap opening Maximum flap opening 100 Flap opening Minimum at ventilation Main ventilation Current ventilation Current flap opening Maximum at ventilation The AQC flap without...

Page 13: ...en determining the flap positions The pressure control will be instantaneously switched off if a ventilation alarm occurs at the main ventilation control If a pressure alarm occurs the pressure contro...

Page 14: ...ndwidth If the bandwidth is too small the heating very quickly reacts to temperature changes The switched heating has a fixed installer adjusted switching hysteresis Minimum maximum heating Limiting t...

Page 15: ...ting immediately after you switch the house to not in use Reduction Limiting the current cooling and to prevent that too much cold air being drawn into the house when the outside tem1perature is low a...

Page 16: ...drop in the house temperature specifically at the bottom of the house If the pressure control was not switched off the air speed and the temperature difference in the house would increase enormously A...

Page 17: ...larm The temperature monitor alarm occurs only when a positive difference is detected not when the temperature drops down COMPENSATIONS CLIMATE CONTROL Compensations ensure that the setting is increas...

Page 18: ...NTILATION Control of optimal ventilation based on the fill ratio The fill ratio is calculated on the basis of the maximum number of animals in the house and the current number of animals in the house...

Page 19: ...minimum ventilation 1 0 C Start outside temperature 15 0 C till 10 0 C Current outside temperature 5 0 C 5 0 C 15 0 C 1 0 C 20 0 100 2 Calculated minimum ventilation 20 0 2 0 18 Current outside tempe...

Page 20: ...pensated pressure is limited by the set minimum and maximum pressure RH The ventilation flap position and set house temperature can be controlled based on relative humidity Absolute RH the water vapou...

Page 21: ...he heaters can switch on Absolute RH outside air lower than the absolute RH house If the RH of the outside air is low the humidity in the house can be removed by increasing the ventilation rate The co...

Page 22: ...use becomes too high this also automatically increases the heating settings The corrected ventilation is limited by the pre set maximum Max Compensation ventilation In this event ventilation is NO LON...

Page 23: ...lation The corrected ventilation is limited by the pre set maximum Max Correction ventilation Compensation current CO2 CO2 compensation start 100ppm factor 1 Factor If 0 0 is set this means that RH co...

Page 24: ...immediately be adjusted to the curve setting The settings obtained from a growth curve are recalculated every hour to achieve a more gradual development of the setting Press function key F3 to display...

Page 25: ...absolute alarm limit is reached This compensation prevents the alarm from being activated unnecessarily when outside temperatures are high However the corrected alarm limit can never be higher than th...

Page 26: ...perature limits and the preset temperature of the control itself GROUPS VENTILATION If the measuring fan is switched off it no longer influences the control and alarm functions of the main ventilation...

Page 27: ...off all flaps are closed all timers are switched off In addition in this screen you can switch the growth curve on off and change the day numbers of the curves New entry Change the setting no to yes...

Page 28: ...hese 2 have been added the amount filled is automatically set to 0 Use keys 0 9 to change the name see page 7 FILLED An overview of the last 5 times that you have entered the filling details in screen...

Page 29: ...Attention Counter readings which are a copy of the counter readings on the PFA 9200 or PFV 9200 are not deleted you can only delete them on the PFA 9200 or PFV 9200 Caution When the counter is cleared...

Page 30: ...1 311 1 314 2 625 Sunday 1 047 1 140 2 187 Saturday 1 098 1 102 2 200 Friday 1 002 1 035 2 037 Thursday 1 049 1 122 2 171 Wednesday 1 053 1 130 2 183 The weekly total is the sum of the counter readin...

Page 31: ...you to quickly switch schedules LIGHT TIMERS Light timers enable a light regulation to be used so that the lights are gradually switched on off A light regulation enables you to create ideal day and n...

Page 32: ...age For feed dosing the amount actually fed is compared to the amount setting Feeding stops when the pre set amount is reached even if the stop time has not been reached yet A feed dosing alarm is gen...

Page 33: ...trol you can set the day number of the dosing curve here If the installer has activated the dosing curves you can use programmable curves to have the amount of water and or feed per animal increase au...

Page 34: ...e consisting of time schedules Standard timer TIME SCHEDULES You can set a maximum of 9 different time schedules Every time schedule can consist of a maximum of 24 periods LIGHT SCHEDULES You can set...

Page 35: ...y Friday etc to Monday If the PL 9400 poultry computer is linked to a feed weighing computer you CANNOT change the setting First day of the week and the setting Beginning new day on the PL 9400 poultr...

Page 36: ...this moment per group of animals Today s mortality or death rate is increased automatically by the value entered after which the entry is erased Dead Today Today s total mortality If you have entered...

Page 37: ...n the sum of the total number of animals of all animal groups added together Entry date The poultry computer uses these Entry date to calculate the animal age Beside that the Entry date is used to fil...

Page 38: ...per name This screen allows you to switch the external alarms on or off max 10 In addition the next screen shows the current status of the input opened or closed and the current alarm status COMMUNICA...

Page 39: ...ounter selected for water dosing or the timer type is set to communication and no PFA 9200 has been installed Invalid silo output The output number does not exist on the module Minimum supply alarm Th...

Page 40: ...for all components although a certain amount of feed has to be dosed Dosage too low The amount of water and or feed dosed is less than the preset minimum amount to be dosed see page 35 Feed detected...

Page 41: ...ion of the filters and flaps Check for air pressure leakage in the house Air leaks can lead to draughts and in summer they can result in unwanted heating due to hot air being drawn in from between the...

Reviews: