Page 24 of 41
GROWTH CURVES
Several growth curves are available for gradual automatic adjustment of
the climate in the house. A growth curve can consist of a maximum of 7
breakpoints.
The current setting is determined on the basis of the growth curve,
depending on the current day number. The poultry computer uses this
calculated setting to control the climate in the house (provided that the
growth curves are on).
Growth curves on/off You can use this setting to switch all curves on
or off simultaneously.
Attention!
●
Relative or absolute temperature setting, see page 10
●
The day numbers in the curve have to be consecutive numbers.
●
If the day number of the first breakpoint is greater than 1, the setting for the first breakpoint
will be maintained until the preset day number.
●
If the temperature compensation is active, the calculated house temperature will immediately
be adjusted to the curve setting.
●
The settings obtained from a growth curve are recalculated every hour to achieve a more
gradual development of the setting.
●
Press function key F3 to display the graph displaying the curve; press function key F3 again
to return to the numerical screen.
: The current curve day number is displayed between brackets behind “Day”.
HOUSE TEMPERATURE
When changing the growth curves of the house temperature you should be aware that there may be controls
which control relative to this temperature, see page 10.
VENTILATION
The temperature setting of the ventilation groups is relative to the house temperature setting.
HEATING / COOLING ETC.
Temperature setting is below 10.0°C:
Temperature setting is relative with respect to the house
temperature setting
Temperature setting is higher than 10.0°C: Temperature setting is an absolute temperature setting.
RH-COMPENSATION
Setting growth curve of RH-compensation
HUMIDIFICATION
Setting growth curve of the humidification.
ANIMAL WEIGHT
Setting growth curve of the animal weight.