Page 6 of 28
FUNCTION KEYS (HELP, GRAPHIC, ALARM, PREVIOUS / NEXT ROOM NUMBER ETC.)
Function key F2 (room status)
Short key to call up the room status.
Function key F3 (graph)
Use this function key to place a graph on a window. The “graph” function is active when the LED in the
function key lights up. You can switch off the “graph” function by pressing the function key again (the
LED in the key is off then).
The values in a graph are linked to the window on the basis of which the graph was drawn up. The graph is
updated automatically when you change the details in the window. Since the position of the graph is determined
automatically, certain details in the window may no longer be visible.
If the details in the window are displayed in graph form, the symbol will be displayed in the top right corner
of the menu line.
Select room
You can only select a room with the same screen content with the
keys.
or
Example:
Room
1
2
3
4
5
Control of inlet flap
based on:
Temperature Ventilation Temperature
Pressure
Ventilation
If the cursor is in room 1 and you press the
key, the settings and measurements for room 3 will be
displayed on the screen. If the cursor happens to be in room 2 and you press the
key, the settings and
measurements for room 5 will be displayed on the screen. If the cursor is in room 4 and you press the
key,
the cursor will remain in room 4.
Alarm key
Short key for alarm screens
Test (alarm test)
: This enables you to test the operation of the alarm
relay (siren). If you enter "yes" in the
Test
line, the alarm relay (siren)
will be switched on for 10 seconds.
You can clear the alarm test time by setting "no" in the
Test
line.
(alarm temporarily off)
:
This enables you to temporarily
switch off the alarm (siren). This does not apply to the hardware
alarms; they cannot be switched off temporarily. The main alarm is
switched off for 30 minutes (the lamp will flash irregularly). The main
alarm is switched on automatically again after 30 minutes. The alarm
relay will de-energize again, causing an alarm, if the cause of the
alarm has not been removed.
You can clear the temporary alarm deactivation time by setting "no" in
the
line.
If the alarm relay has de-energized (alarm delay time has lapsed) the cause of the de-energization of the alarm
relay will be displayed. In addition, you can switch the main alarm on and off. When the main alarm is off, the
LED in the alarm key will flash to indicate that the main alarm is off. The LED in the alarm key lights up if there
is an alarm in one of the rooms and/or central controls.
In addition to the cause of the alarm, the control and the room number where the fault occurred will be
displayed.
The terminal number to which the alarm relates is listed behind “Room” (in this example this is: sensor number
00K01 which is faulty).