INsTALLATIoN
Appliance description
WPE
| 13
ENGL
IS
H
non-domestic environment, e.g. in a small business, as long as
it is used in the same way.
Any other use beyond that described shall be deemed inap-
propriate. observation of these instructions and of instructions
for any accessories used is also part of the correct use of this
appliance.
2.2 General safety instructions
We guarantee trouble-free function and operational reliability
only if original accessories and spare parts intended for the
appliance are used.
- The qualified contractor is responsible for adherence
to all applicable regulations during installation and
commissioning.
- The appliance should only be operated once it is fully in-
stalled and all safety equipment has been fitted.
- Protect the appliance from dust and dirt during building
work.
2.3 Instructions, standards and regulations
Note
observe all applicable national and regional regula-
tions and instructions.
2.4 Test symbols
see type plate on the appliance.
3. Appliance description
The WPE heat pump extension supplements the WPM system
with additional functions. settings for the additional functions
can be made on the programming unit of the WPM heat pump
manager.
The WPE heat pump extension provides:
- Two additional heating circuits with mixer
- A swimming pool controller for primary and secondary
integration of a swimming pool
- Two additional 0-10 V interfaces
- A differential controller
- switching outputs
The WPE heat pump extension:
- Enables incorporation of a second DHW cylinder with sep-
arate DHW program
- Allows cascades of up to six heat pumps
- supplements the basic functions of the WPM heat pump
manager with options for connecting a building manage-
ment system
3.1 Standard delivery
The following are delivered with the appliance:
- 3 TAF PT immersion/contact sensors
- 30 wedges for fixing cables
3.2 Accessories
3.2.1 Required accessories
- WPM heat pump manager
3.2.2 Further accessories
- 2 m TAF PT immersion/contact sensor
- 5 m TAF PT immersion/contact sensor
- FET remote control
4. Installation
4.1 Minimum clearances
≥90
≤60
a
D
00000
70
54
3
1
1 Cable duct
a space for using a screwdriver
f
f
Allow adequate space below the appliance for using a
screwdriver.
We recommend leaving sufficient space to the left or right of
the appliance so that you can hang the front fascia on the side
of the appliance when opening it.
4.2 Installation location
The appliance is designed exclusively for wall mounting.
f
f
Install the appliance to the left or right of the heat pump
manager.
f
f
Install the device on a smooth installation surface. This will
make it easier to lay the electrical cables.
f
f
Ensure that the back of the wall mounting enclosure is not
accessible once mounted.
f
f
Protect the appliance against humidity, dirt and damage.