ZźăĒù
Damage to the appliance and environment
Appliance disposal
f
This symbol indicates that you have to do something. The ac-
tion you need to take is described step by step.
1.3
Units of measurement
Note
All measurements are given in mm unless stated other-
wise.
2. Safety
2.1 Intended
use
This appliance is designed to heat DHW with heat pumps.
Any other use beyond that described shall be deemed inappro-
priate. Observation of these instructions and of instructions for
any accessories used is also part of the correct use of this appli-
ance. Any modifications or conversions to the appliance void all
warranty rights.
2.2 Safety
information
DANGER Scalding
There is a risk of scalding at outlet temperatures in ex-
cess of 43 °C.
!
WARNING Injury
Where children or persons with limited physical, sensory
or mental capabilities are allowed to control this appli-
ance, ensure that this will only happen under supervision
or after appropriate instruction by a person responsible
for their safety.
Children should be supervised to ensure that they never
play with the appliance!
Damage to the appliance and environment
The appliance is under pressure.
During the heating process, expansion water will drip
from the safety valve. If water continues to drip when
heating is completed, please inform your heating con-
tractor.
2.3 Test
symbols
See type plate on the appliance.
3. Appliance
description
The DHW is heated via a smooth tube internal indirect coil. In
addition, a threaded immersion heater and/or flanged immersion
heater can be connected. You can use the appliance to supply one
or several draw-off points.
The appliance is equipped with an inspection flange and thermo-
meter.
The steel cylinder is coated on the inside with special directly ap-
plied „anticor
®
“ enamel and is equipped with a protective anode.
This anode protects the inside of the cylinder from corrosion. The
cylinder is surrounded by foam insulation and a painted sheet
metal jacket.
4. Cleaning, care and maintenance
f
Have the function of the safety assembly and electrical safe-
ty of the fitted accessories regularly checked by a qualified
contractor.
f
Have the protective anode checked by a heating contractor
after the first two years. The heating contractor will then de-
termine the intervals at which it must be checked thereafter.
f
Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
4.1 Scaling
,WXZ^_PaP]d_d[PZQbL_P]OP[Z^T_^WTXP^NLWPL_STRS_PX[P
]L_`]P^?ST^^P__WP^TY^TOP_SPL[[WTLYNPLYOLQQPN_^MZ_S_SP
[P]QZ]XLYNPLYO^P]aTNPWTQP4QLLYRPOTXXP]^TZYSPL_P]T^
TY^_LWWPO_SPSPL_TYRPWPXPY_^X`^_MPOP^NLWPOQ]ZX_TXP_Z
_TXP,SPL_TYRNZY_]LN_Z]bSZVYZb^_SPWZNLWbL_P]\`LWT_d
bTWW_PWWdZ`bSPY_SPYPc_^P]aTNPT^O`P
f
Check the taps/valves regularly. You can remove limescale
deposits at the tap outlets using commercially available de-
scaling agents.
5. Troubleshooting
%|şùŒ
|şń¼
f
V¼ă¼®ź
The outlet flow rate is
low.
The aerator in the tap or
shower head is scaled up
or contaminated.
Clean and/or descale the
aerator or the shower
head.
If you cannot remedy the fault, notify your heating contractor. To
facilitate and speed up your enquiry, please provide the serial
number from the type plate (no. 000000-0000-000000):