WARNING 

 

There are no user serviceable parts on this product.  Attempts to service 
this  product  by  someone  other  then  a  licensed  plumber  or  heating 
technician  could  void  the  warranty,  cause  property  damage,  personal 

injury or loss of life. 
 
A mixing valve does not eliminate the risk of scalding: 
 

 

Set the thermostat as low as practical. 

 

Feel water before bathing or showering. 

 

If anti-scald or anti-chill protection is required, use devices 

specifically designed for such service.  Install these devices in 
accordance with their manufacturer’s instructions. 

 
Install  a  new  Temperature  and  Pressure  Relief  (“T  &  P”)  Valve  in  the 
tapping  on  the  top  of  the  tank  marked  “T&P  VALVE”.    Failure  to  do  so 
could result in property damage, personal injury or death. 
 

 

This Valve must comply with the Standard for Relief Valves and 

Automatic Gas Shutoff devices for Hot Water Supply Systems (ANSI 
Z21.22) 

 

No valve is to be placed between the T&P valve and the tank. 

 

Do not install valves, reducing couplings or other obstructions in the 
relief valve discharge line. 

 

Do not install a T&P valve with a pressure settings in excess of 150 PSI 
or a temperature setting in excess of 210˚F 

 

Pipe the discharge line to a location where hot water discharge will 
not cause injury or damage. 

 

Do not run any portion of the discharge line through a location that 
will be exposed to freezing temperatures. 

 

Pipe he discharge line to allow complete drainage of both the 
discharge piping and the T&P valve. 

 

Hydrogen gas can be produced in a hot water system that has not been 
used for a long period of time (generally two weeks or more).  Hydrogen 
gas is extremely flammable.  To prevent the possibility of injury under these 
conditions, it is recommended that the hot water faucet  be opened for 
several  minutes  at  the  kitchen  sink  before  you  use  any  electrical 
appliance,  which  is  connected  to  the  hot  water  system.    If  hydrogen  is 
present,  there  will  probably  be  an  unusual  sound  such  as  air  escaping 
through the pipe as hot water begins to flow.  There should be no smoking 

or open flame near the faucet at the time it is open. 

 
 
 
 
 

Summary of Contents for SB 150

Page 1: ...Phone 413 247 3380 800 582 8423 Fax 413 247 3369 E mail info stiebel eltron usa com SB 150 SB 200 Glass Lined Indirectly Fired Water Heaters With Single Heat Exchanger INSTALLATION AND OPERATING INST...

Page 2: ...nk opens periodically it may be due to thermal expansion in a closed water supply system Consult a licensed plumber the local plumbing authority or the water supplier Do not plug the Temperature and P...

Page 3: ...o not install valves reducing couplings or other obstructions in the relief valve discharge line Do not install a T P valve with a pressure settings in excess of 150 PSI or a temperature setting in ex...

Page 4: ...50 SB 200 First hour rating gal hr 192 225 Boiler water output btu hr 103 149 116 094 Boiler water flow gal min 8 0 8 0 Coil head loss ft w c 2 6 2 6 Coil surface sq ft m2 12 1 1 12 14 3 1 32 Tank vol...

Page 5: ...5 Dimensions in cm Model SB 150 SB 200 A 5 1 8 13 02 5 1 8 13 02 B 9 3 4 24 76 9 3 4 24 76 C 34 86 36 37 7 8 96 20 D E 50 1 2 128 27 62 3 4 159 38 F 20 1 2 20 1 2...