INSTALLATION
Commissioning
11. Commissioning
11.1 Initial start-up
11.1.1 Setting the air flow rate
Output and energy consumption of the appliance depend on the
pressure drop in the duct system and the resistance of the filters.
Fan stage
Air flow rate
m³/h 0
50: Moisture protection ventilation
This fan stage prevents mould formation using the
factory-set air flow rate of 50 m³/h.
m³/h must be lower than for stage 2
m³/h must be lower than for stage 3
m³/h LWZ 370 plus: 50 - 400
m³/h
LWZ 170 E plus: 50 - 300
The air flow rate of the higher fan stage is automatically selected
if one of the above conditions is not met.
11.2 Shutdown
Even during longer periods away from home, we recommended
that the equipment should be allowed, via the remote control,
to run at switch position 1. If you nevertheless need to take the
appliance out of use for an extended period, switch it off via the
user interface and unplug it from the mains to isolate it from the
power supply.
f
f
Clean or replace filters.
11.3 Recommissioning
f
f
Check whether filters are fitted in the appliance. Never start
the appliance without filters.
f
f
Check whether the condensate drain is damaged or kinked.
12. Settings
12.1 Settings menu
For optimum appliance function, you can change parameters used
to adapt the appliance to the actual installation. Some parameter
settings such as the air flow rates have been set out in the technical
details appertaining your individual building.
Note
Changes to settings not described may only be made by
agreement with the manufacturer. Incorrect settings may
impair the correct appliance function.
12.1.1 How to set parameters
Selecting the settings menu
f
f
Press menu in standard mode.
The settings menu is displayed ("SET").
26
�0
4�
15
�0
06
4
Enabling the settings menu
f
f
Press menu again to enable the settings menu.
26
�0
4�
15
�0
06
5
Selecting parameters
f
f
Use the plus or minus key to select the parameter you want
to set.
26
�0
4�
15
�0
06
6
1
2
1 Parameter number
2 Parameter value