background image

www.stiebel-eltron.com 

FCR 28 Si | 

17

EN

GL

ISH

INSTALLATION 

 

Settings

11.  Settings

Temperature

85°C

60°C

35°C

26

�02

�7

9�

002

8

f

f

The temperature can be freely adjusted.

f

f

Factory setting 60 °C (the temperature selector clicks into 

place at this setting).

11.1  Limiting the temperature selection

Appliance type with external temperature selector

You can adjust the temperature selection limitation beneath the 

temperature selector.
Factory setting: 60 °C

f

f

Set the temperature selector to "cold" and isolate the appli-

ance from the power supply.

f

f

Remove the temperature selector and the control panel 

cover.

f

f

Loosen the two screws from the outside and pull the thermo-

stat down to remove.

f

f

Once you have removed the limiter disc from the thermostat 

axis, the maximum temperature can be reached.

f

f

Tighten the thermostat screws again and replace the tem-

perature selector and control panel cover.

12.  Troubleshooting

Fault

Cause

Remedy

The water does not 

heat up. 

The high limit safety cut-

out has responded because 

the controller is faulty.

Replace the thermostat and 

press the high limit safety 

cut-out reset button.

 

 

 

The high limit safety cut-

out has responded because 

the temperature has fallen 

below -15 °C.

Press the reset button. 

 

 

 

 

A heating element is faulty. 

 

Replace the heating ele-

ment or flanged immersion 

heater.

 

 

 

The high limit safety cut-

out has responded because 

an indirect coil in the same 

cylinder is set too high.

Limit the maximum tem-

perature of the indirect 

coil. 

The safety valve drips 

when the heating is 

switched off.

The valve seat is contami-

nated. 

Clean the valve seat. 

 

1

26

�0

2�

79

�0

01

5

1  High limit safety cut-out reset button

13.  Maintenance

 

WARNING Electrocution

Before any work on the appliance, disconnect all poles 

from the power supply.

13.1  Checking the safety assembly

f

f

Check the safety assembly regularly.

13.2  Descaling the flanged immersion heater

f

f

Descale the flanged immersion heater only after it has been 

removed.

13.3  Replacing the heating elements and protective 

pipe

f

f

When installing heating elements or a protective pipe, en-

sure that the components are electrically isolated from the 

flange.

Summary of Contents for FCR 28/120 Si

Page 1: ...OPERATION AND INSTALLATION UTILISATION ET INSTALLATION BEDIENING EN INSTALLATIE Heizflansch Flanged immersion heater Corps de chauffe Verwarmingsflens FCR 28 120 Si FCR 28 180 Si FCR 28 270 Si FCR 28...

Page 2: ...the heating elements and protective pipe 17 14 Specification 18 14 1 Dimensions immersion depths and connections 18 14 2 Wiring diagrams and connections 18 14 3 Data table 20 GUARANTEE ENVIRONMENT AN...

Page 3: ...emperatures in ex cess of 43 C WARNING Injury The appliance may be used by children aged 8 and up and persons with reduced physical sensory or mental capabilities or a lack of experience provided that...

Page 4: ...ommercially available des caling agents f f Regularly activate the safety valve to prevent it from becom ing blocked e g by limescale deposits 6 Troubleshooting Fault Cause Remedy The water does not h...

Page 5: ...ge pipe of the safety valve with a constant downward slope and in a room free from the risk of frost f f The safety valve discharge aperture must remain open to the atmosphere 8 Appliance description...

Page 6: ...immersion heater The contactors must be switched inde pendently of one another by the thermostats and the high limit safety cut out respectively see chapter Specifica tion Wiring diagrams and connect...

Page 7: ...high limit safety cut out has responded because the controller is faulty Replace the thermostat and press the high limit safety cut out reset button The high limit safety cut out has responded because...

Page 8: ...cables PG 13 5 2 Entry electrical cables PG 21 Mating flange 245 219 205 83 14 280 26_02_79_0013 14 2 Wiring diagrams and connections FCR 28 120 Si part number 075140 FCR 28 180 Si part number 075131...

Page 9: ...6 5 4 L3 L2 L1 4 5 3 1 2 85_02_79_0002 1 Heating element 9 kW connected load 9 x 1 kW 18 kW connected load 9 x 2 kW 27 kW connected load 9 x 3 kW 36 kW connected load 9 x 4 kW 2 Thermostat 3 High limi...

Page 10: ...00 300 300 Versions IP rating IP24 IP24 IP24 IP24 IP24 IP24 Dimensions External flange diameter mm 280 280 280 280 280 280 Immersion depth mm 325 325 325 450 450 450 Torque Nm 80 80 80 80 80 80 Weight...

Page 11: ...Y Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 Fax 0387 7468 26...

Reviews: