cFK 5 | 9
f
f
push the appliance down so that
it sits fully on the wall mounting
bracket.
f
f
insert the locking tab into the
top aperture of the wall mount-
ing bracket.
f
f
turn the locking tab with a
screwdriver until it clicks into
place.
10.1 Power supply
f
f
connect the appliance to the
power supply with the mains
plug supplied.
11. Specification
11.1 Dimensions and connec-
tions
E
b01 entry electrical cables
i13
Wall mounting bracket
11.2 Wiring diagram
F
r1 electric heating element
n1 temperature controller
F1 safety temperature controller
11.3 Data table
CFK 5
073685
Electrical data
connected load
kW
0.5
power supply
1/n ~ 230 v
Dimensions
height
mm
387
Width
mm
170
depth
mm
110
Weight
Weight
kg
1.2
Versions
Frost protection setting
°c
6
ip rating
ip20
safety category
ii
colour
white
Values
setting range
°c
6-45
installation
7. Safety
only a qualified contractor should
carry out installation, commission-
ing, maintenance and repair of the
appliance.
7.1 General safety instruc-
tions
We guarantee trouble-free operation
and operational reliability only if the
original accessories and spare parts
intended for the appliance are used.
7.2 Regulations, standards
and instructions
DANGER Electrocution
Carry out all electrical con-
nection and installation
work in accordance with relevant
regulations.
!
Damage to the appliance
and environment
observe the type plate. the
specified voltage must match the
mains voltage.
Note
observe all applicable na-
tional and regional regula-
tions and instructions.
8. Appliance descrip-
tion
8.1 Standard delivery
delivered with the appliance:
-
1 wall mounting bracket
-
1 locking tab
-
2 screws
-
2 rawl plugs
9. Preparations
9.1 Installation in bath-
rooms
DANGER Electrocution
Install the appliance ex-
clusively outside safety
zone 2.
C
0
safety zone 0
1
safety zone 1
2
safety zone 2
3
safety zone 3
f
f
ensure that you maintain the
safety clearances of safety
zone 2 towards bath tubs, show-
er cubicles and washbasins.
9.2 Installation site
DANGER Fire
f
ensure that the wall on
which the appliance is
mounted is resistant to tempera-
tures up to at least 90 °c.
f
f
ensure that the installation site is
not below a socket.
f
f
ensure that the installation site is
at least 10 cm away (to the side)
from a socket.
9.3 Minimum clearances
A
f
f
ensure that the minimum per-
missible clearances to adjacent
objects are maintained.
f
f
ensure that the hot air can es-
cape from the appliance without
obstruction.
10. Mounting
D
1 locking tab
2 Wall mounting bracket
3 latching stay
f
f
secure the wall mounting brack-
et to the wall with suitable rawl
plugs and screws.
f
f
offer the back of the appliance
to the wall mounting bracket
and guide the apertures in the
appliance back over the latch-
ing stays in the wall mounting
bracket.
Guarantee
For guarantees please refer to the respective terms and conditions of supply for your country.
!
The installation, electrical connection and first operation of this appliance should be carried out by a qualified
installer.
!
The company does not accept liability for failure of any goods supplied which have not been installed and
operated inaccordance with the manufacturer‘s instructions.
Environment and recycling
Recycling of obselete appliances
Appliances with this label must not be disposed off with the general waste. They must be collected separately and disposed off
according to local regulations.
Summary of Contents for CFK 5