background image

INSTALLATION 

Appliance description

18 |  

WS, WS-G

3.  Appliance description

The appliance provides the required amount of dHW at the 

preferred temperature at the draw-off points. This occurs with-

in the output limits of the appliance. Heating water is distrib-

uted to the connected radiators.

4.  Cleaning, care and 

maintenance

A damp cloth is sufficient for cleaning the casing. Never use 

abrasive or corrosive cleaning agents.
The heat exchanger requires regular cleaning, depending on 

water quality. Have the appliance cleaned by a qualified con-

tractor after no more than 2 years. The qualified contractor 

will then determine the intervals at which it should be cleaned 

thereafter.

5.  Troubleshooting

Problem

Cause

Remedy

dHW and radiators do 

not heat up.

The central pump is not 

working. 

Check whether the cen-

tral pump is running. 

 

 

The heating system is 

not working. 

Check whether the 

heating system is free 

from faults.

If you cannot remedy the fault, contact your qualified contrac-

tor. To facilitate and speed up your request, provide the num-

ber from the type plate (000000-0000-000000).

WS

000000-0000-000000

Made in Germany

d

00000

56

83

7

INSTALLATION

6.  Safety

Only a qualified contractor should carry out installation, com-

missioning, maintenance and repair of the appliance.

6.1  General safety instructions

We guarantee trouble-free function and operational reliability 

only if original accessories and spare parts intended for the 

appliance are used.

6.2  Instructions, standards and regulations

 

Note

Observe all applicable national and regional regula-

tions and instructions.

7.  Appliance description

For dHW heating, cold water flows to the plate heat exchanger. 

The "thermo fluid system" measuring system detects the dHW 

demand. Some of the heating water from the heating water 

flow is channelled over the heat exchanger to heat the dHW 

to the required temperature. dHW from the cold water con-

nection is channelled through the heat exchanger and heated 

as required. dHW flows from the heat exchanger to the dHW 

outlet. The maximum water volume can be limited with the 

flow limiter in the dHW outlet.
A cold water outlet supplies the draw-off points from a cold 

water distributor inside the appliance.
A water hammer arrestor is fitted for pressure protection.
Heating water from the heat generator is distributed by the 

appliance to the radiators via the dirt filter.

 

Note

See chapter "Add-on options" for descriptions of the 

add-on options.

8.  PROFI SELECT modular system

The PROFI SeLeCT modular system consists of 4 components:

 - Base unit
 - Add-on options
 - Output modules
 - Accessories

Summary of Contents for 234657

Page 1: ...DIENUNG UND INSTALLATION OPERATION AND INSTALLATION Profi Select Wohnungsstation Trinkwarmwasser und Heizung Profi Select heat interface unit for DHW and heating WS 1 WS 2 WS 3 WS 4 WS G 2 WS G 3 WS G...

Page 2: ...e deren Nichtbeachtung schwere Verletzungen oder Tod zur Folge haben kann VORSICHT Hinweise deren Nichtbeachtung zu mittelschweren oder leichten Verletzungen f hren kann BEDIENUNG 1 Allgemeine Hinweis...

Page 3: ...t Eine andere oder dar ber hinausgehende Benutzung gilt als nicht bestimmungsgem Zum bestimmungsgem en Ge brauch geh rt auch das Beachten dieser Anleitung sowie der Anleitungen f r eingesetztes Zubeh...

Page 4: ...Reparatur des Ger tes darf nur von einem Fachhandwerker durchgef hrt werden 6 1 Allgemeine Sicherheitshinweise Wir gew hrleisten eine einwandfreie Funktion und Betriebssi cherheit nur wenn das f r das...

Page 5: ...6 Temperaturregler Thermo Fluid System 7 Schmutzfilter mit Sieb 8 Platten W rme bertrager 8 1 1 Einstellm glichkeiten Temperaturregler TFS Skalierung Temperaturregler TFS Regelbereich 40 60 C Bemerkun...

Page 6: ...f f Sie k nnen vorhandene Montagesch chte sowie als Ein bauoption oder Zubeh r erh ltliche Aufputz und Unter putz Geh use f r die Wandmontage nutzen 10 1 1 Aufputz Aufputz Geh use montieren D000007518...

Page 7: ...r dem Anschluss gr ndlich durch f f Verlegen Sie die Rohrleitungen bis zum Ger t f f Schlie en Sie die Rohrleitungen spannungsfrei an den Ab sperrventilen des Ger tes an f f Pr fen Sie die richtige Po...

Page 8: ...artungsvertrages f f bergeben Sie diese Anleitung 14 Wartung WARNUNG Stromschlag Trennen Sie bei allen Wartungsarbeiten das Ger t vom Stromnetz indem Sie das Ger t ber eine Trennvorrichtung mit einer...

Page 9: ...auf Innengewinde G c04 Kaltwasser Auslauf Innengewinde G c06 Warmwasser Auslauf Innengewinde G d33 W rmeerzeuger Vorlauf Innengewinde G d34 W rmeerzeuger R cklauf Innengewinde G e01 Heizung Vorlauf In...

Page 10: ...Edelstahl kupferge l tet Edelstahl kupferge l tet Edelstahl kupferge l tet Edelstahl kupferge l tet Edelstahl gel tet Edelstahl gel tet Edelstahl gel tet Auslegungstemperatur C 55 55 55 55 55 55 55 An...

Page 11: ...6 kg h prim r 771 Leistung kW 33 50 WS G2 10 kg h prim r 785 562 641 753 926 458 508 566 638 728 864 00 Leistung kW 21 21 22 4 23 8 25 1 21 00 22 40 23 80 25 10 26 50 27 90 11 kg h prim r 879 623 717...

Page 12: ...458 494 537 584 638 378 407 440 472 512 548 Leistung kW 25 10 26 80 28 50 30 10 31 80 33 40 25 10 26 80 28 50 30 10 31 80 33 40 25 10 26 80 28 50 30 10 31 80 33 50 13 kg h prim r 522 573 627 692 767 4...

Page 13: ...890 573 616 666 720 774 836 Leistung kW 37 70 40 20 42 70 37 70 40 20 42 70 45 20 47 70 37 70 40 20 42 70 45 20 47 70 50 20 WS 4 WS G4 12 kg h prim r 461 501 544 591 648 713 411 443 476 512 555 598 37...

Page 14: ...lte Teile werden unser Eigentum F r die Dauer und Reichweite der Garantie bernehmen wir s mtliche Material und Montagekosten Soweit der Kunde wegen des Garantiefalles aufgrund gesetzli cher Gew hrleis...

Page 15: ...n Deutschland Entsorgung von Altger ten in Deutschland Ger teentsorgung Die mit diesem Symbol gekennzeichneten Ger te d r fen nicht mit dem Hausm ll entsorgt werden Als Hersteller sorgen wir im Rahmen...

Page 16: ...may result in serious injury or death CAUTION Failure to observe this information may result in non se rious or minor injury OPERATION 1 General information 16 1 1 Relevant documents 16 1 2 Safety in...

Page 17: ...Anyotherusebeyondthatdescribedshallbedeemedinappro priate Observation of theseinstructionsand of theinstructions for any accessories used is also part of the correct use of this appliance 2 2 Safety...

Page 18: ...ld carry out installation com missioning maintenance and repair of the appliance 6 1 General safety instructions We guarantee trouble free function and operational reliability only if original accesso...

Page 19: ...rt filter with strainer 8 Plate heat exchanger 8 1 1 TFS temperature controller adjustment options Scale TFS temperature controller control range 40 60 C Notes 1 40 2 42 3 44 4 47 Recommended setting...

Page 20: ...casings for installation on finished or unfinished walls which are available as installation options or accessories can be used for wall mounting 10 1 1 Finished walls Installing the casing for finis...

Page 21: ...the heating system before con nection f f Route the pipework up to the appliance f f Connect the pipework to the shut off valve of the appli ance ensuring that it is stress free f f Check the correct...

Page 22: ...a maintenance contract f f Hand over these instructions 14 Maintenance WARNING Electrocution Always isolate the appliance from the power supply when performing maintenance work using an isola tor with...

Page 23: ...Female thread G c04 Cold water outlet Female thread G c06 DHW outlet Female thread G d33 Heat source flow Female thread G d34 Heat source return Female thread G e01 Heating flow Female thread G e02 H...

Page 24: ...s steel cop per brazed Stainless steel cop per brazed Stainless steel cop per brazed Stainless steel brazed Stainless steel brazed Stainless steel brazed Design temperature C 55 55 55 55 55 55 55 Conn...

Page 25: ...1 4 33 5 16 kg h primary 771 Output kW 33 50 WS G2 10 kg h primary 785 562 641 753 926 458 508 566 638 728 864 00 Output kW 21 21 22 4 23 8 25 1 21 00 22 40 23 80 25 10 26 50 27 90 11 kg h primary 879...

Page 26: ...422 458 494 537 584 638 378 407 440 472 512 548 Output kW 25 10 26 80 28 50 30 10 31 80 33 40 25 10 26 80 28 50 30 10 31 80 33 40 25 10 26 80 28 50 30 10 31 80 33 50 13 kg h primary 522 573 627 692 76...

Page 27: ...0 13 kg h primary 501 544 594 648 710 782 447 483 519 558 605 656 404 432 465 497 533 573 Output kW 27 30 29 10 30 90 32 70 34 50 36 30 27 30 29 10 30 90 32 70 34 50 36 30 27 30 29 10 30 90 32 70 34 5...

Page 28: ...nische wijzigingen Salvo error o modificaci n t cnica R tt till misstag och tekniska ndringar f rbeh lls Excepto erro ou altera o t cnica Zastrze one zmiany techniczne i ewentualne b dy Omyly a techni...

Reviews: