![STIEBEL ELTRON 200156 Operation And Installation Download Page 19](http://html1.mh-extra.com/html/stiebel-eltron/200156/200156_operation-and-installation_1376756019.webp)
INSTALLATION
Installation
www.stiebel-eltron.com
SB-VTI |
19
EN
GL
ISH
Installing the HP-SB 3/150 flanged immersion heater
D
00000
82
22
5
2
10
13
11
9
8
7
6
5
4
3
12
1
1
Sheet metal casing earth
6
Flange cover
11
Earth cable
2
Flange gasket
7
Screw 4.2x16
12
Flange D = 180x5
3
Flange earth screw
8
Washer 4.3
13
Heating element
4
Temperature selector
9
M12x25 screw
5
Control indicator
10
Washer 13
Electrical connection
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
The connection to the power supply must be in the form
of a permanent connection. Ensure the appliance can be
separated from the power supply by an isolator
that disconnects all poles with at least 3 mm contact
separation.
Material losses
Observe the type plate. The specified voltage must match
the mains voltage.
Note
Ensure that the appliance is earthed.
f
f
Feed the connecting cable into the control panel interior.
f
f
Connect the load (see chapter "Specification / Wiring dia-
grams and connections").
N
N
G
H
A
E
R
D
00000
82
22
6
HP-SB 3/150
A Thermal fuse
B Temperature selector
C Control indicator
D Heating element
E Sheet steel casing
G Cylinder
H Rod anode
R Electrical resistance 560 Ω
Flange earth screw