INSTALLATION
Safety
www.stiebel-eltron.com
SB-VTI |
17
EN
GL
ISH
INSTALLATION
6. Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
6.1 General safety instructions
We can only guarantee trouble-free function and operational reli-
ability if original spare parts intended for the appliance are used.
6.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
7. Appliance description
7.1 Required accessories
Depending on the static pressure, safety assemblies and pressure
reducing valves are available. These type-tested safety assemblies
protect the appliance against unacceptable excess pressure.
7.2 Additional accessories
Flanged immersion heaters are available as accessories.
If it is not possible to insert a rod anode from above, install a
segmented anode.
8. Preparation
8.1 Installation site
f
f
Always install the appliance in a room free from the risk of
frost and near the draw-off point.
26
�0
5�
20
�0
00
4
f
f
Ensure the floor is level. Use the adjustable feet to compen-
sate for any unevenness in the floor.
f
f
Ensure the floor has a sufficient load bearing capacity (see
chapter "Specification / Data table").
f
f
Observe the room height and height when tilted (see chapter
"Specification / Data table").
Minimum clearances
The minimum side clearances can be swapped between left and
right.
≥300
≥300
≥800
≥500
≥100
≥100
≥500
D
00000
82
28
3
f
f
Maintain the minimum clearances.
8.2 Transport
For transportation, the appliance is secured to the pallet with
metal brackets.
f
f
Remove the screws from the pallet.
f
f
Turn the metal brackets to the inside of the adjustable feet
under the appliance.
Removing the appliance from the pallet
!
Material losses
Rolling the appliance off the pallet can damage the sheet
metal casing.
f
f
Tilt the appliance using the adjustable feet to remove it from
the pallet.
f
f
Set the appliance down on the floor on the adjustable feet.