ARCS / ARCS Blue
Upgradable readers
Installation instructions
ARCS / ARCS Blue
Lecteurs évolutifs
Notice d’installation
ARCS / ARCS Blue
Lectores escalables
Procedimiento de instalación
conforme con
NOM-024 -SCFI-2013
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1114C06- Page
5
sur
15
-
Ed. 08/04/2019
STid reserves the right to make change without notice, for the purpose of product improvement.
Procedure to add the biometric (SE6) or 125 kHz module (SE8)
Declaration of compliance
STid declares that the ARCS-X reader is compliant with the essential requirements of the Directives RED 2014/53/EU and RoHs 2011/65/EU. A copy of our
declaration is available on request from
This device complies with Part 15 of the FCC rules and with ISED’s license–exempt RSSs. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired operation.
Note: the manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications
could void the user’s authority to operate the equipment.
This device complies with the safety requirements for RF exposure in accordance with RSS-102 issue 5 for conditions of use.
“DEEE Pro” Member
In accordance with the provisions of the Environment Code, STid finances the collection, decontamination and recycling of WEEE provided by
ESR-RECYLUM, to which STid adheres and to which it has transferred its regulatory responsibilities as a Producer.
STid recommends that owners of used equipment who wish to dispose of it return it as WEEE by contacting ESR / RECYLUM in order to benefit
from the solutions at no additional cost of collecting and recycling used equipment. More information on
- Check that the cable length that comes out of the module does not exceed 0.39 in. If it
does, push the excess cable into the module housing.
- Connect the cable of the module to connector J9.
You should not have a loop
(1)
.
-
Insert the module into the reader slot (until you hear a “click” for SE6)
- Cut the base as shown in the drawing
(2)
.
- Place the module on the base (i.e. Mounting), use the 2 screws provided with
the module
(3)
.
(3)
(3)
(1)
Slot for the
passage of
the biometric
cable
SE6
(2)
To pass the module cable into
the
support,
cut
out
the
preformed part of the support.
Option:
Reinforcement plate to rigidify the
assembly:
- Standard/keyboard
biometric module: Ref. SE7-
ARC-DE.
- Touch screen
biometric module: Ref. SE7-
ARC-F.
Screw
SE8
(3)
(3)
Slot for the passage
of the 125 kHz
module cable
STid guarantees the good working order, compliance, technical
support and after-sales service of the readers and modules (SE6 and
SE8) that are installed as explained above, without any internal or
external modifications.