SCIENTIFIC TECHNOLOGIES INC.
R
12
BINARY L
AST
& F
IRST
B
LOCKED
M
ODE
Reports, in binary format, 2 bytes,
representing the last and first beams blocked,
e.g., 0x9E 0x17. No delimiters nor spaces are
included, just 2 consecutive data bytes.
Syntax:
BINARY LBB+FBB
Note: This command is not available on the
Windows Software check-off boxes. Use the
Terminal Window to enter this command. See
Section 4 Windows Software for details.
BINARY F
IRST
& L
AST
B
LOCKED
& N
UMBER
OF
O
BJECT
M
ODE
Reports, in binary format, 3 bytes, representing
the first beam blocked, last beams
blocked, and the number of objects in the
system, e.g., 0x17 0x9E 0x01. No delimiters nor
spaces are included, just 3 consecutive data
bytes.
Syntax:
BINARY FBB+LBB+NOBJ
Note: This command is not available on the
Windows Software check-off boxes. Use the
Terminal Window to enter this command. See
Section 4 Windows Software for details.
BINARY L
AST
& F
IRST
B
LOCKED
& N
UMBER
OF
O
BJECT
M
ODE
Reports, in binary format, 3 bytes,
representing the last beam blocked, first beams
blocked, and the number of objects in the
system, e.g., 0x9E 0x17 0x01. No delimiters nor
spaces are included, just 3 consecutive data
bytes.
Syntax: BINARY LBB+FBB+NOBJ
Note: This command is not available on the
Windows Software check-off boxes. Use the
Terminal Window to enter this command. See
Section 4 Windows Software for details.
S
ERIAL
T
IMING
C
OMMANDS
If you are using the serial reports, you must
set a timing command.
The scanner has two serial timing modes:
synchronous timing and software trigger. If the
scanner does not respond to your commands
press
ESC
twice and
Enter
.
S
YNCHRONOUS
R
EPORTING
M
ODE
The synchronous reporting mode gives
serial reports continuously at set intervals.Two
commands control this mode: one sets the timer
interval between reports; the other sets the
scanner for synchronous serial reports.
Syntax:
TSYNC
n
where
n
is the time in
milliseconds between serial data reports.
Syntax:
SYN
sets the scanner to use
synchronous timing and puts the scanner in the
reporting mode. Press
ESC
twice after this
command to continue with setup.
Three auxiliary reporting functions can be used
in the synchronous timing mode. These are
functions which can help in processing data
from the scanner.
Delta Mode
Delta Mode inhibits serial reports when the
beam status has not changed from the previous
report.
Syntax:
DELTA Y
turns on this mode
DELTA N
turns off this mode.
Section 6 – Serial Output