background image

               

   

       

 

   

emergency  stop  button  for  2  seconds,  leave  the  button  and  the  machine  enter  into 
parameters  setting  interface.  The  speed  “+”&  “-”  button  can  be  released.The  speed 
window  show  “0”and  also  the  same  as  time  window.  The  speed  window  shows 
parameters code, while the time window show the corresponding parameter data. 
2)  Press  “Start/Pause”button  for  eight  times,  the  speed  window  will  show  “8”as   
automatic lubricant distance. The time window show the original automatic lubricant 
distance. In this status, the distance data can be reset through pressing the speed “+”& 
“-” button. Setting over.    Press the “Start/Pause”button to save the settings and also 
shift  to  the  time  setting  interface.  The  speed  window  will  show  “9”  and  the  time 
window  will  show  the  original  automatic  lubricant  time.In  this  status,  the  time  data 
can  be  reset  through  pressing  the  speed  “+”&  “-”  button.  Setting  over,  pressing  the 
“Start/Pause”button to save the settings and also shift to the next parameters. Finally 
press the emergency stop button and then release it to back to the ready model. 

    Notice:   

1)  Owing  to  the  different  using  situation  of  each  club,  if  necessary,  please  set  the 
automatic lubricant parameters as above step. 
2) Check the oil in the oiler every each months and add the lubrication timely. 
 
 
 
 

Summary of Contents for S-900

Page 1: ...COMMERCIAL TREADMILL S 900 USER MANUAL...

Page 2: ...2 SPECIFICATION 1 3 SAFETY INSTRUCTION 2 3 4 PACKING LIST 3 5 ASSEMBLY 3 4 5 6 6 PANNEL 7 8 7 DEBUGGING 8 8 USAGE INSTRUCTION 8 9 10 9 WINDOWS 10 11 10 MAINTENANCE 11 12 11 ERRORS SOLUTIONS 12 13 12 A...

Page 3: ...3 0HP Max power of motor 7HP Working temperature 0 40 Speed range 1 0 20 0 km h Time range 0 00 99 59 min sec Distance range 0 00 99 9 km Calorie range 0 999 Kcal Heart rate range 50 256 times minites...

Page 4: ...results is only for reference 30 seconds later will have a more accurate heart rate visual ahead Avoid stepping the edge of the running space If first use hold the handrail with two hands to keep bala...

Page 5: ...in case of any unauthorized users 24 This machine complied with SC type under EN 957 6 4 PACKING LIST Remark 12 pcs 12 25 hexagon socket screw will be needed for a treadmill 4pcs as spare parts 5 ASSE...

Page 6: ...by drawing instruction STEP 1 Remove the packing remove the motor shield Tools Phillips screwdriver Assembly instructions 1 Take one Phillips screwdriver 2 Take of the screws from the motor cover 3 Pu...

Page 7: ...on line assembly digital watch Tools T inner hexagon spanner M10 Instruction for assembly This installation step should be two people cooperation 1 Electronic communications leads to dock with the pos...

Page 8: ...switch in front of the treadmill 2 Press START PAUSE on the console to check if the treadmill is working well 3 If the treadmill works well place the motor cover in the right place 4 A cross screwdri...

Page 9: ...defined 8 Speed reduction button Press the button to reduce the speed of the treadmill 9 Speed acceleration Press the button to reduce the speed of the treadmill 10 Speed direct selection area in the...

Page 10: ...from bottom parameter value time window shows the default time 30 00 minutes can be used to speed up slow down button to change the time value After the machine start to set the time value of recipro...

Page 11: ...nt In manual mode pressing accelerator slow down button or press speed direction button can change the speed of the treadmill In the process of fixed program it can not change the speed value manually...

Page 12: ...isplayed in manual mode a ladder diagram is displayed in fixed program safe is displayed when emergency stop available and safe also displayed in Time window Pause is displayed in matrix when pause A...

Page 13: ...of the left clockwise or counter clockwise adjust the adjusting screw on the right If the running belt to the right can adjust to the right of the adjusting screw clockwise or counter clockwise adjus...

Page 14: ...nverter power module temperature rise is too high Examination content Machine in operation process whether converter cooling fan to stop working SAFE The abrupt stop switch is wrong Cause Stop device...

Page 15: ...ough pressing the speed button Setting over Press the Start Pause button to save the settings and also shift to the time setting interface The speed window will show 9 and the time window will show th...