background image

Mount the switch on to the machine frame and the 
actuator on to the opening edge of the door. Always try 

to mount the switch on non-ferrous material. (

Ferrous 

materials may reduce the switching distance.) 

Use the tamper proof screws provided to make more 
secure.  

Do not use the safety switch as a door stop. Leave a 
minimum of 50 mm between any adjacent switches. 

WRONG!

Minimum 50mm

Leave a 2mm Gap

to prevent damage.

Dimensions in MM [Inches] 

DIMENSIONS 

MOUNTING 

The MF-2  safety switches can approach each other from 
most angles. When the guard is closed the targets on the 
printed face of the switch and actuator must be aligned.  

EN 1088  

Provides some mounting suggestions, see example 
opposite.  

When fixing the safety switch to a sliding door (A), 
ensure that when the door is opened (B) it is not easily 
accessible, helping prevent the system being overridden 

IMPORTANT: a minimum distance or gap of 2mm must 
be maintained between the switch and actuator to 
assure proper switch actuation. Failure to maintain this 
minimum gap may lead to nuisance faults on the switch 
controller unit.

2mm

Summary of Contents for MF Series

Page 1: ...associated with guards EN 60947 5 3 Safety of Machinery Specification for low voltage switchgear and control gear Interlocked guards where additional security required Door locking is not required Food and Beverage packing filling systems Diary Pharmaceutical Paper Industry Can Forming and Filling Aluminum Steel Plastic Semiconductor Manufacture Assembly Description A Declaration of Conformity can...

Page 2: ... DIMENSIONS MOUNTING The MF 2 safety switches can approach each other from most angles When the guard is closed the targets on the printed face of the switch and actuator must be aligned EN 1088 Provides some mounting suggestions see example opposite When fixing the safety switch to a sliding door A ensure that when the door is opened B it is not easily accessible helping prevent the system being ...

Page 3: ...les of this type of relay are listed below OMRON STI SR131A SR231A See diagram below OPERATION 1 POWER ON GATE CLOSED When the switch has power and the actuator is in place the LED will be GREEN The Normally Closed contact will be closed and the Normally Open contact will be open 2 POWER ON GATE OPEN When the switch has power and the actuator is out of range the LED will be RED The Normally Closed...

Page 4: ...es are described as normally closed N C i e With the guard closed actuator in place and the machine able to be started In the interest of product development specifications are subject to change without notice Document No 563 400 v3 Internal Fuse N O N C 1Amp Fast Acting External Fuse Customer Supplied AC DC 500mA Fast Acting IP Rating IP67 Vibration Shock 50 100Hz 10g Operating Temperature 10 to ...

Page 5: ...stems Machine Automation Controllers MAC Programmable Controllers PLC Operator interfaces HMI Distributed I O Software Drives Motion Controls Servo AC Drives Motion Controllers Encoders Temperature Process Controllers Single and Multi loop Controllers Sensors Vision Proximity Sensors Photoelectric Sensors Fiber Optic Sensors Amplified Photomicrosensors Measurement Sensors Ultrasonic Sensors Vision...