STI MF Series Operating Instructions Download Page 3

CONTACTS, CONNECTIONS & FUSES 

CONNECTIONS to a Safety Relay 

NOTE 

MF-2 Contacts shown when the actuator is in place. 

MF-2 SAFETY SWITCH 

Example connection diagram to a Safety Relay for CAT 3. 

The safety relay should require 1 x N/C + 1 x N/O input with a low inrush current input switching circuit. Examples of this 

type of relay are listed below  

OMRON STI 

    SR131A / SR231A (See diagram below) 

OPERATION 

1  POWER ON, GATE CLOSED  

When  the  switch  has  power  and  the  actuator  is  in  place,  the 
LED  will  be  GREEN.  The  Normally  Closed  contact  will  be 

closed and the Normally Open contact will be open.  

2  POWER ON GATE OPEN 

When the switch has power and the actuator is out  of range, 
the  LED  will  be  RED.  The  Normally  Closed  contact  will  be 
open and the Normally Open contact will be closed. 

SAFETY RELAY 

SR131A / SR231A  

Summary of Contents for MF Series

Page 1: ...associated with guards EN 60947 5 3 Safety of Machinery Specification for low voltage switchgear and control gear Interlocked guards where additional security required Door locking is not required Food and Beverage packing filling systems Diary Pharmaceutical Paper Industry Can Forming and Filling Aluminum Steel Plastic Semiconductor Manufacture Assembly Description A Declaration of Conformity can...

Page 2: ... DIMENSIONS MOUNTING The MF 2 safety switches can approach each other from most angles When the guard is closed the targets on the printed face of the switch and actuator must be aligned EN 1088 Provides some mounting suggestions see example opposite When fixing the safety switch to a sliding door A ensure that when the door is opened B it is not easily accessible helping prevent the system being ...

Page 3: ...les of this type of relay are listed below OMRON STI SR131A SR231A See diagram below OPERATION 1 POWER ON GATE CLOSED When the switch has power and the actuator is in place the LED will be GREEN The Normally Closed contact will be closed and the Normally Open contact will be open 2 POWER ON GATE OPEN When the switch has power and the actuator is out of range the LED will be RED The Normally Closed...

Page 4: ...es are described as normally closed N C i e With the guard closed actuator in place and the machine able to be started In the interest of product development specifications are subject to change without notice Document No 563 400 v3 Internal Fuse N O N C 1Amp Fast Acting External Fuse Customer Supplied AC DC 500mA Fast Acting IP Rating IP67 Vibration Shock 50 100Hz 10g Operating Temperature 10 to ...

Page 5: ...stems Machine Automation Controllers MAC Programmable Controllers PLC Operator interfaces HMI Distributed I O Software Drives Motion Controls Servo AC Drives Motion Controllers Encoders Temperature Process Controllers Single and Multi loop Controllers Sensors Vision Proximity Sensors Photoelectric Sensors Fiber Optic Sensors Amplified Photomicrosensors Measurement Sensors Ultrasonic Sensors Vision...

Reviews: