Appendix B Terminal Menu Reference
RFI-9256 Radio Modem User Manual
Page 78 of 109
B.2.2.3 (L) Link Control Menu
*** Link Control Menu ***
Main Port: ARQ Retries = 50
Network Fail Timer = 5000ms
Online Request Timer = 1000ms
(A) Number of Retries for ARQ
(F) Network Fail Timer
(O) Online Request Timer
(Esc) Previous Menu
Enter Choice:
Figure 43: Link control menu
Number of Retries for ARQ:
Sets the number of ARQ retries to be used on the selected port. See
section B.1.1 on page 71 for more information.
Network Fail Timer:
Sets the network fail timer for the selected port. See section B.1.1 on page 71
for more information.
Online Request Timer:
Sets the online request timer for the selected port. See section B.1.1 on page
71 for more information.
B.3 (S) Serial Port Configuration Menu
*** Port Selection Menu ***
Main Port: 19200 Baud, No Parity, 8 Data, 1 Stop, No Flow
Main Port: Packet Timers: Output = Disabled, Input = Disabled
Aux Port: 19200 Baud, No Parity, 8 Data, 1 Stop, No Flow
Aux Port: Packet Timers: Output = Disabled, Input = Disabled
(M) Main Port
(A) Aux Port
(Esc) Previous Menu
Enter Choice:
Figure 44: Serial port selection menu
Main Port:
Allows the serial port settings for the main port to be configured as shown in Figure 45.
Aux Port:
Allows the serial port settings for the auxiliary port to be configured.