27
09/24999842
Installation
SHE control panel TRZ Basic 4A/UP
Legend RBH/3A
Switch SHE Open
Switch SHE Closed
LED SHE Open
OK
LED operating OK
LED malfunction
Anschlussdose/
Junction box
Motor
=
Motor
=
braun
brown
blau
blue
O
3
O
3
O
3
O
4
O
4
O
4
P
P
P
P
1
P
1
P
1
S
S
S
S
2
S
2
S
2
mehrere Lüftungstaster
Auf / Zu gemeinsam = Stop
several vent switches
open / closed together = Stop
mehrere Lüftungs-
taster mit Sicht-
anzeige LTA 25
several vent
switches with
visual display LTA 25
Mehrere Antriebe,
gesamte Stromaufnahme max. 4 A
several drives
total power consumption max. 4 A
1 2 3
8 10 11
8 9 10 11
letzter Antrieb
last drive
Lüftungstaster
Vent switch
Netz/
230 V/50Hz
Mains
Motor 24 V DC
max. 3 A
RWA-Bedienstelle/
SHE man. call point
autom. Melder/
autom. detector
6
6
5
5
4
4
8
8
1
1
3
3
12 13 14 15 16 17
mehrere RWA-Bedienstellen RBH/3A
several SHE man. call points RBH/3A
mehrere autom.
Melder
several autom.
detectors
18 19
Leitungsüberwachung:
Überwachungsdioden in der letzten oder
einzigen Anschlussdose einklemmen.
Line monitoring: monitor diodes to connect
in the last or in the unique junction box.
Linienabschluss: in der letzten oder
einzigen RWA-Bedienstelle beiliegenden
Endwiderstand 10k (
W
) einklemmen.
Line termination: connect provided
10k end resistor (
W
) in the last or unique
SHE manual call point.
blau
blue
braun
brown
L N PE
1 2 3
8 9 10 11
12 13 14 15 16 17
18 19
Ü
be
rw
ac
hu
ng
/
M
on
ito
rin
g
au
to
m
. M
el
de
r
+
-
au
to
m
. d
et
ec
to
r
M
ot
or
-
M
ot
or
+
Anschlussklemmen in der Steuerzentrale
Terminals in the control panel
Keine RWA-Bedienstelle und/oder autom. Melder, Linienabschluss (
W
) in der Zentrale aufklemmen.
No SHE man. call point and/or autom. detector, connect line termination (
W
) in the control panel.
N
et
zl
ei
te
r/
N
eu
tra
lle
ite
r/
S
ch
ut
zl
ei
te
r/
ph
as
e
co
nd
.
ne
ut
ra
l c
on
d.
P
E
c
on
du
ct
or
M
as
se
/
LE
D
“
Lü
ftu
ng
A
uf
”/
Ta
st
e
ZU
/
Ta
st
e
AU
F/
G
N
D
LE
D
“
Ve
nt
o
pe
n”
sw
itc
h
cl
os
ed
sw
itc
h
op
en
L
ro
/
E
D
t
LE
D
re
d
G
N
D
LE
D
g
el
b/
LE
D
y
el
lo
w
D
r
LE
g
ün
/
E
D
r
n
L
g
ee
Ta
st
e
ZU
/
s
s
w
itc
h
cl
o
ed
Ta
st
e
AU
F/
s
t
h
op
en
w
ic
1+
1+
5
5
2
2
4
4
AM/...
AM/...
1 2 3 4 5 6
letzter Melder
last detector
SSD...
UTD...
oder/
MSD...
or
19 18
+
Sockel USB...
Base USB...
1 2 3 4 5 6
1. Melder
1. detector
Linienabschluss: im letzten
oder einzigen autom. Melder
Endwiderstand 10k (
W
) ein-
klemmen.
Line termination: connect
provided 10k end resistor (
W
)
in the last or unique
automatic detector.
12
17
18
19
Line monitoring:
monitor diodes to connect in the last
or in the unique junction box.
several drives
total power consumption
max. 4 A
several vent
switches with
visual display
LTA 25
several vent switches
open / closed together
= Stop
Line termination: connect
provided 10k end resistor (Ω) in
the last or unique SHE manual
call point.
Line termination:
connect provided 10k
end resistor (Ω)
in the last or unique
automatic detector.
several SHE man. call
points RBH/3A
several autom.
detectors
Base USB...
1. detector
SSD...
UTD...
or
MSD...
Junction box
No SHE man. call point and/or autom. detector, connect line termination (Ω) in the control panel.
SHE man. call point
Autom. detector
Vent switch
Motor 24 V DC
max. 3 A
Mains
230 V / 50 Hz
Terminals in the control panel
Phase conductor
Motor -
GND
GND
Autom. de
Neutral conductor
PE conductor
Motor +
Monitoring
LED “V
ent open”
Switch closed
Switch open
LED green
LED red
LED yellow
Switch closed
Switch open
Autom. detector -
Motor
=
Motor
=
last drive
brown
brown
blue
blue
last detector
Monitoring diodes
24 V DC
24 V DC
1 2 3
- +
-
+
Polarity of the motor voltage for open/close