background image

2

Electrical Connections

Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting

the unit to a power source.  The specifications on the data plate supersede any future discussion.

The standard unit is equipped with an eight (8) foot power cord that requires a 115 Volt, 60 Cycle, 1 Phase

properly grounded

 electrical receptacle.  The power cord comes with a 3 prong plug for grounding pur-

poses.  Any attempt to cut off the grounding spike or to connect to an ungrounded adapter plug will void the

warranty, terminate the manufacturers responsibility and could result in serious injury.

The circuit must be protected with a 15 or 20 ampere fuse or breaker.  The unit must be isolated on a circuit

and not plugged into an extension cord.

OPERATION

Initial Start Up

After satisfying the installation requirements, the unit is ready to start.  The unit will start when the power

cord is connected to the required power source.  If the compressor does not start when the unit is initially

plugged in, check to make sure that the temperature control is not in the ‘off ‘ position.  Allow the unit to run

a minimum of two hours before loading it with product.  When loading the unit with product, take care not to

block the air flow at the back of the cabinet as this would affect the performance of the cabinet.

Temperature Control

The Temperature Control is located on the back wall of the cabinet liner and is factory set to maintain an

average cabinet temperature of 35 to 40 Deg. F.  To obtain colder temperatures turn the Temperature

Control knob clockwise and visa versa.  Allow the unit a minimum of one hour to respond to a control setting

adjustment.

Defrost

Your Silver King unit is an automatic defrost unit.  No additional plumbing is required.  The frost buildup on

the evaporator coil will clear each time the compressor shuts off and the condensate will drain to the

condensate evaporator pan where it will evaporate.  It is important that the unit be level so the condensate

can drain properly.

MAINTENANCE

Preventative maintenance is minimal although these few steps are very important to continued operation

and maximizing the life of the appliance.

Cabinet Surfaces

The cabinet interior and exterior are stainless steel.  These surfaces should be cleaned periodically with a

solution of warm water and mild soap.  After cleaning the surfaces should be rinsed with clean water and

wiped dry with a soft cloth.  Stainless steel cleaners can also be used.  Should a surface become stained,

do not attempt to clean with an abrasive cleaner or scouring pad.  Use a soft cleanser and rub with the grain

of the metal to avoid scratching the surface.   Always rinse well and dry after cleaning.  Do not use chlori-

nated cleaners.

Condenser

Periodically, dust on the condenser filter must be cleaned.  The condenser filter is located on the  right side

of the front bottom grill.  To clean it simply vacuum it or brush it to clear the filter screen.  This will need to be

done regularly to maintain the compressor warranty!

90033

MODEL_____________________ SERIAL NO._______________________ DATE INSTALLED___________________

Summary of Contents for Silver King SKRB27

Page 1: ...e Company 1600 Xenium Lane North Minneapolis MN 55441 3787 Phone 763 553 1881 Technical Manual and Replacement Parts List Refrigerators FRONT BREATHING Specifications Subject to Change Without Notice MODEL SKRB27 MODEL SKRB27D ...

Page 2: ...lean water and wipe dry Location When locating your new Silver King unit convenience and accessibility are important considerations but the following installation guidelines must be observed Always avoid locating the unit adjacent to an oven heating element or hot air source which could ad versely affect the performance of the unit If the unit is not on casters it is designed to be sealed to the f...

Page 3: ... average cabinet temperature of 35 to 40 Deg F To obtain colder temperatures turn the Temperature Control knob clockwise and visa versa Allow the unit a minimum of one hour to respond to a control setting adjustment Defrost Your Silver King unit is an automatic defrost unit No additional plumbing is required The frost buildup on the evaporator coil will clear each time the compressor shuts off and...

Page 4: ... elegir una ubicación para su nueva unidad Silver King debe tener en cuenta la conveniencia y facilidad de acceso pero debe seguir las siguientes pautas de instalación Siempre evite colocar la unidad cerca de un horno elemento calefactor o fuente de aire caliente que pueda afectar el funcionamiento de la unidad Si la unidad no está apoyada sobre rueditas está designada para ser sellada al piso con...

Page 5: ...eratura promedio de aproximadamente 1 66 a 4 Grados Centígrados 35 a 40 Grados Fahrenheit Para obtener temperaturas más bajas gire la perilla de Control de temperatura en el sentido de las agujas del reloj y viceversa Espere un mínimo de una hora para que la unidad responda a un ajuste de control Descongelamiento Su unidad Silver King posee descongelamiento automático y no se requieren trabajos de...

Page 6: ...minez l emplacement de votre nouvelle unité Silver King la commodité et l accessibilité sont des considérations importantes mais les conseils d installation qui suivent doivent être observés Évitez toujours de placer l unité dans le voisinage d un four d un élément chauffant ou d une source d air chaud qui affecterait le fonctionnement de l unité Si l unité n est pas sur des roulettes elle est con...

Page 7: ...des températures plus froides tournez le bouton de réglage de température dans le sens horaire et vice versa Laissez à l unité au moins une heure pour répondre à un réglage de fixation de régulation Dégivrage Votre unité Silver King est une unité à dégivrage automatique Aucune tuyauterie supplémentaire n est requise L accumulation de givre sur le serpentin de l évaporateur sera dégagée chaque fois...

Page 8: ...asser ab und wischen sie trocken Aufstellort Für die Wahl des Aufstellortes Ihres neuen Silver King Gerätes sind Bequemlichkeit und Zugänglichkeit wichtige Kriterien folgendes muss jedoch beachtet werden Stellen Sie das Gerät nie direkt neben eine Wärmequelle wie einen Herd oder Heizkörper denn dies würde die Leistung des Gerätes beeinträchtigen Falls das Gerät nicht auf Rollen gestellt wird muss ...

Page 9: ...ren erreichen drehen Sie den Temperaturregler im Uhrzeigersinn wollen Sie die Temperatur erhöhen drehen Sie ihn gegen den Uhrzeigersinn Das Gerät braucht mindestens eine Stunde um auf die neue Einstellung des Temperaturreglers zu reagieren Abtauen Ihr Silver King Gerät taut automatisch ab Dafür sind keine zusätzlichen Installationen nötig Immer wenn der Kompressor nicht läuft wird das Eis auf der ...

Page 10: ...9 4 6 20 12 17 18 19 8 9 54 52 53 10 11 27 21 23 50 51 45 38 49 51 44 37 40 48 OPPOSITE SIDE 47 41 39 46 14 15 16 24 13 1 2 3 5 7 22 35 32 33 34 28 29 30 31 25 26 36 42 43 OPPOSITE SIDE ...

Page 11: ... 115 60 21251 2 FAN MOTOR 220 50 21251 3 26 FAN BLADE 4 5 99751 27 CASTER 2 WHEEL 99641 28 DRIER 22677 29 COMPRESSOR KIT 115V 60HZ 10343 08 COMPRESSOR KIT 220V 50 60HZ 10343 27 30 31 COMPRESSOR ELECTRICAL KIT 115V RELAY OVERLOAD 10344 08 COMPRESSOR ELECTRICAL KIT 220V RELAY OVERLOAD 10344 27 32 GROMMET COMPRESSOR MOUNT 20481 33 CLIP HAIRPIN 98106 34 WASHER COMPRESSOR MOUNT 22401 35 POWER CORD 115V...

Page 12: ...11 WIRING DIAGRAM Models SKRB27 SKRB270 SKRB27W 115 VAC 60Hz 1 Phase OR 220 VAC 50Hz 1 Phase FORM NO 25961 09 00 Printed in U S A ...