Stern SWAR Installation And Maintenance Manual Download Page 4

4

5

iNStaLLatioN

Step 3 –  poWeriNG tHe HaND Dryer

Warning: 

Work on electrical installations may only be carried out by 

certified electricians or by instructed persons working under the guidance 

and supervision of a certified electrician, in accordance with local 

regulations.

Important Note: 

SWAR is available only as a 110 volt model or 

a 220 volt model.

To power the hand dryer, a certified electrician 

must remove the dryer unit cover and hardwire it to 

the main power line. 

To remove the dryer unit cover, remove the two 

Allen screws with the included Allen key.

Warning

For installation of the SWAR hand dryer system, follow the directions below.

iNStaLLatioN

Step 1 – WaLL moUNtiNG 

1

Firmly attach the wall support to the 

wall.

Note: Ensure the wall support is 

installed leveled. 

Screws not uncluded.

2

Place the SWAR unit on the support. 

make sure to pass the electrical wire(s) 

and valves through the holes in the 

SWAR.

3

Secure the SWAR cabinet to the wall 

by installing the masonry anchors and 

screws provided.

Step 2 –coNNect tHe Water SyStem

For SWAR with cold water option:

 

connect the water system to inlet B1

B1

B2

                        

For SWAR with premixed water option:

connect hot water system to B1 and cold water 

system to B2

Notes:

Thoroughly flush the water supply lines before connecting them to the SWAR.

Do not allow dirt, Teflon tape or metal particles to enter the faucet.

Shut off water supply when done.

IMPORTANT:

 Water and electrical supplies should be kept OFF throughout the entire 

installation.

Note: Before installing the SWAR, flush water lines and shut off all valves.

Summary of Contents for SWAR

Page 1: ...1 Installation and maintenance guide Soap Water Air REVOLUTION...

Page 2: ...formation in this document is provided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular pu...

Page 3: ...se a pressure reducing valve Sensor range faucet Self adjusting sensor Adjustable with remote control Min 80mm Max 300mm Sensor range soap dispenser Factory Set 150mm adjustable by remote control 30 1...

Page 4: ...Firmly attach the wall support to the wall Note Ensure the wall support is installed leveled Screws not uncluded 2 Place the SWAR unit on the support Make sure to pass the electrical wire s and valves...

Page 5: ...o the power splitter Plug the transformer into the main power line B3 3 Wait about 10 seconds for the Faucet and the Soap Dispenser sensors to complete their self adjustment 10 SECONDS ABOUT 4 Put you...

Page 6: ...diaphragm from the solenoid valve and examine it for dirt In case it is dirty or clogged wash it under running water and reassemble it Do not attempt to dismantle the solenoid valve if you are unfamil...

Page 7: ...even if the power source is disconnected To get back to the self adjustment mode use the ADJ button only Entrance to the self adjustment mode This button operates faucets including a self adjusting s...

Page 8: ...al to perform any kind of activity in front of the sensor without operating the system for example cleaning Faucets and or soap dispensers will remain shut for 1 minute when this button is pressed onc...

Page 9: ...am dispenser components including pipes Troubleshooting faucet PROBLEM INDICATOR CAUSE SOLUTION No water coming out of the faucet LED in the sensor does not flash once when user s hands are within the...

Page 10: ...onnectors properly so that the white o ring is not visible PROBLEM Corrective actions If the dryer will not run HAZARD BE SURE TO TAKE SUITABLE PRECAUTIONS TO AVOID SHOCK First ensure that the breaker...

Page 11: ...18 06 18 01500371 A 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com...