maINTENaNcE

filter cleaning instructions

This tap is provided with a stainless steel filter preventing foreign particles to enter the 

lines. If the water flow has decreased, this may be because the filter is clogged. The filter 

can be cleaned as follows:

1. Shut-off the water shut off valve. 

2. Disconnect the water supply pipe from the adaptor and disassemble the filter from it. 

3. Wash the filter under running water.

4. Reassemble the parts.

5. Restore the incoming water supply. 

6. Make sure that there is no water leakage. 

care and cleaning of chrome and special finishes

DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or the like. 

Use of any prohibited cleaning or maintenance products or substances could damage the 

surface of the faucet. For surface cleaning of faucet use ONLY soap and water, then wipe 

dry with clean cloth or towel. When cleaning bathroom tile, the faucets should be protected 

from any splattering of harsh cleansers.

If system chemical disinfection is practiced, chlorine can be used (calculated chlorine 

concentration of 50mg/l maximum in water per one hour dwell time) at service interval 

frequency.

sETTINGs aDjusTmENT

delay In tIme:

 It is recommended to change the delay in time for 

flush valves for urinals or toilets only. 

If required, the delay in time can also be modified in faucets as 

follows:
Press the IN button. Wait until a quick flashing of the LED in the 

sensor eye is perceived. Then, press + to increase the delay in time 

and – to reduce it.

delay out tIme: 

This button allows modifying the water flow time 

after the user removes his hands from the faucet. A delay out time 

close to 0 will save more water. An increased delay out time will make 

the user experience more comfortable.  

If required, the delay out time can be modified as follows:
Press the OUT button. Wait until a quick flashing of the LED in the 

sensor eye is perceived. Then, press + to increase the delay out time 

and – to reduce it.

24 houR hygIene Flush: 

This model includes a 24 hours hygiene 

flush which is disabled. To activate the hygiene flush, press the clock 

button. Wait until a quick flashing of the LED in the sensor eye is 

perceived. Then press + to activate the hygiene flush. To disable it 

again, press – to deactivate it. 

comFoRt Flush: I

f your model includes a Comfort flush setting, it can 

be activated by pressing the flush button. 
When the button is pressed, one blink of the LED in the sensor eye is 

perceived. The pre-programmed flush cycle will take place then.

The Comfort flush cannot be interrupted or deactivated by pressing any 

button until it is over.

temPoRaRy oFF FunctIon: 

This function is ideal to perform any kind 

of activity in front of the sensor without operating the system (for 

example, cleaning). 

The faucet will remain shut for 1 minute when this button is pressed 

once. To cancel this function and to return to normal operation press 

the On/Off button again or wait 1 minute.

Reset button: 

This function restores all the factory settings except 

for the sensor range. If required, press the Reset button and without 

releasing it, press the + button once.

NoTE: 

to enter the self adjusting mode, use the adj button. to change the sensor 

range, use the Range button.

Summary of Contents for Extreme CS B

Page 1: ...1 1 Installation and maintenance guide extreme CS WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER Extreme CS B Extreme CS E Extreme CS DP B Extreme CS DP E ...

Page 2: ...hout notice to discontinue or change the features designs materials and other specifications of its products and to either permanently or temporarily withdraw any of the forgoing from the market All information in this document is provided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular p...

Page 3: ...ual power input box with inlet nipple and filter 1 x Transformer exterme cs DP Pack contents E VERSIONS 1x Dual power input box with inlet nipple and filter 1 x Transformer 1 x Spout and attachments incl electronic unit 1 x Wall rosette 1 x Elbow connection with corrugated tube 1 x Secure panel 4 x Screws and anchors 1 x Dual power input box with inlet nipple and filter ...

Page 4: ... applicable codes and regulations Care and cleaning of chrome and special finishes DO NOT use steel wool or cleansing agents containing alcohol acid abrasives or the like Use of any prohibited cleaning or maintenance products or substances could damage the surface of the faucet For surface cleaning use ONLY soap and water then wipe dry with clean cloth or towel When cleaning bathroom tile the fauc...

Page 5: ...NDS 2 If the automatically adjusted sensor range is not satisfactory to your purposes please refer to the section entitled Settings adjustment STEP 1 INSTALLING THE FAUCET 1 Shut off the water supply 2 Cut an adequate sized hole in the wall for the dimensions of the faucet base see Technical Data 3 Install the faucet base firmly to the roughing wall 4 Attach the temporary protective cover over the...

Page 6: ...ntil a quick flashing of the LED in the sensor eye is perceived Then press to increase the range and to reduce it Every push will increase or decrease one level Note Once you have changed the detection range with the remote control the distance will be remembered by the sensor even if the power source is disconnected To get back to the self adjustment mode use the ADJ button only Entrance to the s...

Page 7: ...e it Delay OUT time This button allows modifying the water flow time after the user removes his hands from the faucet A delay out time close to 0 will save more water An increased delay out time will make the user experience more comfortable If required the delay out time can be modified as follows Press the OUT button Wait until a quick flashing of the LED in the sensor eye is perceived Then pres...

Page 8: ...put box using the Allen key provided Remove the old battery and replace it with a new 9V battery Lithium battery is recommended Close the box lid and tighten it with the screw Important Spent batteries should not be disposed of with normal household waste Contact your local authority for information on waste disposal and recycling Spare Parts 10 Pack Sensor Kit 07220412 10 Pack Solenoid valve kit ...

Page 9: ...r Filter or aerator is clogged Water flow diminished Troubleshooting Security Mode If the sensor is covered for more than 90 sec the faucet will automatically shut off water flow To return to normal operation remove any blockage to re establish operation Y Stern Engineering Ltd warrants that its electronic products will be free of defects in material and workmanship during normal use for two years...