INSTALLATION AND MAINTENANCE GUIDE

NEPTUNE SHOWER PANEL B / E  

1000 TB  / 1000 TE 

Summary of Contents for 601410

Page 1: ...1 INSTALLATION AND MAINTENANCE GUIDE NEPTUNE SHOWER PANEL B E 1000 TB 1000 TE ...

Page 2: ...ION INFO 3 4 PACK CONTENTS 5 7 INSTALLATION 8 10 SETTINGS ADJUSTMENT 11 12 BATTERY REPLACEMENT 13 MAINTENANCE Filters cleaning instructions Care and cleaning of chrome and special finishes 14 SPARE PARTS LIST 15 WARRANTY 16 TROUBLE SHOOTING ...

Page 3: ...ater pressure for B E models 0 5 8 0 bar 7 116 PSI Recommended water pressure for 1000 B E models 0 5 5 0 bar 7 72 5PSI Maximum hot and cold pressure difference 2 0 bar Preset sensor range 450 20 mm Max Hot water supply 65 C Short term thermal disinfection temperature 70 C WARNING danger of scalding Flow rate 9 LPM Flow restrictor located in the shower head NEPTUNE SHOWER PANEL 1000 B 602410 NEPTU...

Page 4: ...u obtain the missing parts WARNINGS Do not install facing a mirror or any other electronic system operated by an infrared sensor To prevent reflection problems it is recommended to keep a minimum distance of 1 50 meters between the faucet and any other objects PREPARATION FOR INSTALLATION Flush water supply lines thoroughly before installing the faucet Do not allow dirt Teflon tape or metal partic...

Page 5: ...included 1 x Shower panel with Prox sensor and attachments 1 x Shower head 9000 9 LPM 1 x Shut off valve 1 2 3 x Screws 10X1 1 2 3 x anchors 1 x Allen Key 2 mm 1 x Allen Key 2 5 mm 1 x Allen Key 3 mm 1x Support 1 x Filter IP 67 BATTERY BOX IP 68 ENCAPSULATED TRANSFORMER B VERSION E VERSION ...

Page 6: ...ncluded 1 x Shower panel with Prox sensor and attachments 2 x Shut off valves 1 2 2 x Filters 1 x Shower head 9000 9 LPM 3 x Screws 10X1 1 2 3 x anchors 1 x Allen Key 2 mm 1 x Allen Key 2 5 mm 1 x Allen Key 3 mm 1x Support IP 67 BATTERY BOX IP 68 ENCAPSULATED TRANSFORMER B VERSION E VERSION ...

Page 7: ...m the prox sensor to the solenoid valve is connected 4 For battery operated versions Connect the other cable coming from the prox sensor to the battery box connector For transformer operated versions a Connect the extension cable coming out of the waterproof power cable pass through to the encapsulated transformer connector b Assure that the power supply cable and the prox sensor cable are connect...

Page 8: ...ead panel If you do not wish to restrict the flow remove the flow restrictor with an 8mm Allen key 6 Connect the shut off valve s to the water inlet s at the top cover of the shower panel IMPORTANT Make sure that the filter s is are installed between the shut off valve s and the water inlet s 7 Mount the shower panel on the support 8 Secure the shower panel bottom cover to the wall using a screw 9...

Page 9: ... to 38 C position The anti scalding knob must correspond to the 38 C stop in the stop ring without moving the spindle 3 Tighten the regulation knob screw THE MIXER IS NOW CALIBRATED ACCORDING TO THE SITE SPECIFIC CONDITIONS The shower has been factory calibrated to 38 C under ideal installation conditions Due to variations in site conditions the mixed water temperature may need adjustments to matc...

Page 10: ...8 SETTINGS ADJUSTMENT DETECTION RANGE DELAY IN TIME SECURITY TIME FLOW TIME DELAY OUT TIME TEMPORARY OFF FUNCTION RESET HYGIENE FLUSH WAVE WAVE WAVE WAVE WAVE PROX PROX PROX PROX PROX PROX PROX ...

Page 11: ... the sensor eye is perceived Then press to increase the one level and to reduce it every push will increase or decrease one level NOTE Once you have changed the detection range with the remote control this dis tance will be remembered by the sensor even if the power source is disconnected SECURITY TIME The Security time prevents continuous running of water due to reflections or vandalism By defaul...

Page 12: ...rceived Then press to activate the hygiene flush To disable it again press to deactivate it Temporary Off function This function is ideal to perform any kind of ac tivity in front of the sensor without operating the system for example cleaning The shower will remain shut for 2 minutes when this button is pressed once To cancel this function and to return to normal operation press the On Off button...

Page 13: ...er to open and close the solenoid valve In this case the battery level management system does not allow the solenoid valve to open Instead of providing an opening and closing pulse the systems provides two closing pulses BATTERY REPLACEMENT INSTRUCTIONS BATTERY REPLACEMENT 1 Unscrew the 2 screws at the bottom of the battery cover located at the bottom cover of the panel 2 Pull out the battery cove...

Page 14: ...P67 battery box attached on it back into place If separated please remember to reattach the battery box to the the battery cover with the Velcro ribbon 5 Screw in the 2 screws at the bottom of the battery cover located at the bottom cover of the panel In order to avoid entering the adjusting mode wait 10 seconds after replacing the battery before operating the system IMPORTANT Spent batteries shou...

Page 15: ... s and wash it them under running water 4 Reassemble the filter s 5 Reconnect the cut off valve s to the water inlet s at the top cover of the shower panel 6 Turn on the water supply Make sure that there is no water leakage Care and cleaning of chrome and special finishes DO NOT use steel wool or cleansing agents containing alcohol acid abrasives or the like Use of any prohibited cleaning or maint...

Page 16: ...06530052 TRANSFORMER 06522097 PIPE NIPPLE KIT 07246016 NEPTUNE SHOWER PANEL 1000B 1000E SEALS AND SCREWS KIT 07210124 INLET NIPPLE KIT 07246013 MOUNTING KIT 07280009 THERMOSTATIC CARTRIDGE 07110014 NUT FOR THERMOSTAT 07055137 THERMOSTATIC HANDLE KIT 07110021 ADAPTER FOR HANDLE KIT 07260018 WAVE ON OFF SENSOR P FOR SHOWER PANEL 07220256 PROX SENSOR P FOR SHOWER PANEL 07220164 SOLENOID BS HOUSING KI...

Page 17: ... the purchase price of the product If you believe that you have a warranty claim contact your Stern Distributor Dealer or Plumbing Contractor Please be sure to provide all pertinent information regarding your claim including a complete description of the problem the product model number the date the product was purchased from whom the product was purchased and the installation date Also include yo...

Page 18: ...o long The battery must be replaced 3 Battery is completely used up 4 Unit is in Security Mode Eliminate cause of reflec tion 5 Sensor is picking up re flections from the washbasin or another object Connect the electronic unit connectors to the solenoid 1 Connectors between the electronic unit and solenoid are disconnected 3 Red light in the sen sor flashes once when user s hand body are within th...

Page 19: ......

Page 20: ...18 03 16 01500238 B 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com sternusa sternfaucets com ...