Summary of Contents for 350700

Page 1: ...1 E L E C T R O N I C L A V A T O R Y F A U C E T TUBULAR DM INSTALLATION AND MAINTENANCE GUIDE ...

Page 2: ...ORMATION 4 5 FAUCET INSTALLATION 6 8 SETTINGS ADJUSTMENT 9 BATTERY REPLACEMENT INSTRUCTIONS How to replace the battery at Tubular DMB 10 MAINTENANCE Filter cleaning instructions Care and cleaning of chrome and special finishes 11 TROUBLE SHOOTING 12 SPARE PARTS LIST 13 LIMITED WARRANTY ...

Page 3: ...re reducing valve for reduction Sensor Range Self adjusting sensor Adjustable with remote control Minimum Sensor Range 80 mm Maximum Sensor Range 300 mm Security time 90 seconds Adjustable with remote control Hot Water Supply Max 70 C TUBULAR DMB 350700 Electronic faucet for cold or premixed water to be powered by battery TUBULAR DME 350750 Electronic faucet for cold or premixed water to be powere...

Page 4: ...t the parts are included TUBULAR DME 1 1x Tap and attachments 2 1x Solenoid valve housing filter and adapter 3 1x Transformer 4 1x Allen key 3 1 2 3 4 1 2 3 4 TUBULAR DMB 1 1x Tap and attachments 2 1x Solenoid valve housing filter and adapter 3 1x Battery box 4 1x Allen key ...

Page 5: ...rnings Do not install the system facing a mirror or any other electronic system operated by an infra red sensor To prevent reflection prob lems it is recommended to keep a minimum distance of 1 50 meters between the fau cet and any other objects Preparation for Installation Flush water supply lines thoroughly before installing the faucet Do not allow dirt Teflon tape or metal particles to enter th...

Page 6: ...k O Ring Gasket Disk Hexagonal nut Step 3 Connecting the water supply 1 Fit the pipe to the housing of the solenoid valve Important inlet and outlet should follow the indicating arrow at the solenoid housing 2 Fit the water supply inlet to the adapter at the solenoid valve housing Note Make sure that the filter is assembled between the housing of the solenoid valve and the adapter Important Tubula...

Page 7: ...from the sink 2 For Tubular DME Plug the Transformer in to the electricity socket and connect the connectors Transformer 3 After you have connected the power source Battery or Transformer wait 10 seconds in order to allow the system to set the ideal sensor range Then the product will be ready for use 4 Turn on the central water supply and the shut off valves 5 Check for leaks 6 If the automaticall...

Page 8: ...st by pressing once on one of the function buttons After pressing once on a specific function button a quick flashing of the red light at the front of the sensor will occur At this stage you can change the setting by pressing the or the buttons every push will increase or decrease one level After finishing the adjustment turn the water supply back on DETECTION RANGE Press to increase detection ran...

Page 9: ... the red light of the sensor eye is perceived Then press to increase the security time and to reduce it DELAY IN TIME The delay in time prevents unwanted activations It is recommended to change the delay in time for flush valves for urinals or toilets only If required the delay in time can be modified also in faucets as follows Press the IN button Wait until a quick flashing of the red light of th...

Page 10: ... 1 minute when this button is pressed once To cancel this function and to return to normal operation press the On Off button again or wait 1 minute 7 8 9 RESET BUTTON This function restores all the factory settings except for the sensor range If required press the Reset button and without releasing it press the button once SETTINGS ADJUSTMENT Note To enter the self adjusting mode use the ADJ butto...

Page 11: ... a new 9V battery Lithium battery is recommended 4 Close the box Important Tubular DM was supplied with Stern s new Self Adjusting Sensor The ideal sensor range for the specific location will be set automatically again after changing the battery Check that there are no objects in front of the sensor after the battery replacement was completed After you have connected the power source wait 10 secon...

Page 12: ... Wash the filter under running water b Reassemble the parts c Restore the incoming water supply d Make sure that there is no water leakage Care and cleaning of chrome and special finishes DO NOT use steel wool or cleansing agents containing alcohol acid abrasives or the like Use of any prohibited cleaning or maintenance products or substances could damage the surface of the faucet For surface clea...

Page 13: ... by a sudden increase in the water supply pressure that the backcheck prevents from dropping even after water supply pressure drops under 8 bars Debris or scale in diaphragm 1 Sensor is dirty or covered 2 Sensor is picking up reflections from the washbasin or another object Filter or aerator is clogged Replace battery Increase the range Decrease the range The battery must be replaced Eliminate cau...

Page 14: ... Remote control Mixing valve for one inlet models IP 67 Battery box with 6 x 1 5V AA batteries IP 67 Transformer box with 300 mA transformer Power splitter 2 ways Power splitter 3 ways Power splitter 4 ways Cat No 07220056 Cat No 07230002 Cat No 07231001 Cat No 06530008 Cat No 06522025 Cat No 06009015 Cat No 07100005 Cat No 200060 Cat No 06530020 Cat No 06530021 Cat No 06001001 Cat No 06001002 Cat...

Page 15: ...rise see STERN Warranty The guarantee does not cover faults labor costs or damage caused by incorrect installation and or maintenance wear and tear battery or water composition This includes but is not limited to the following Incorrect installation inversions of supply pipes Pressures or temperatures exceeding recommended limits Improper manipulation tampering bad or lapsed maintenance Foreign bo...

Page 16: ... Yavne Israel Tel 972 8 9326000 Fax 972 8 9326025 export sternfaucets com www sternfaucets com 15 Gan Rave Blvd 81222 Gan Rave Yavne Israel Tel 972 8 9326000 Fax 972 8 9326025 export sternfaucets com www sternfaucets com 06 10 01500022 ...