9
SETTINGS ADJUSTMENT
DELAY OUT TIME
: This button allows modifying the water flow time
after the user removes his hands from the faucet. A delay out time
close to 0 will save more water. An increased delay out time will make
the user experience more comfortable. If required, the delay out time
can be modified as follows:
Press the OUT button. Wait until a quick flashing of the red light in the
sensor eye is perceived. Then, press + to increase the delay out time
and – to reduce it.
24 HOUR HYGIENE FLUSH
: If you have a compatible model with a 24
hours hygiene flush it is possible to enable and disable it . To activate
the hygiene flush, press the clock button. Wait until a quick flashing of
the red light in the sensor eye is perceived. Then press + to activate the
hygiene flush or – to deactivate it.
TEMPORARY OFF FUNCTION
: This function is ideal to perform any
kind of activity in front of the sensor without operating the system (for
example, cleaning). The faucet will remain shut for 1 minute when this
button is pressed once. To cancel this function and to return to normal
operation press the On/Off button again or wait 1 minute.
RESET BUTTON
: This function restores all the factory settings except
for the sensor range. If required, press the Reset button and without
releasing it, press the + button once.
NOTE:
To enter the self adjusting mode, use the ADJ button. To change the sensor
range, use the RANGE button.