8
SETTINGS ADJUSTMENT
DETECTION RANGE
: This faucet was supplied with a self adjusting
sensor. The ideal detection range for the specific location will be set
automatically. Only if necessary, use the remote control to adjust the
sensor range as follows:
Press the
RANGE
button. Wait until a quick flashing of the red light in
the sensor eye is perceived. Then, press
+
to increase the range and
–
to reduce it. Every push will increase or decrease one level.
NOTE:
Once you have changed the detection range with the remote control,
the distance will be remembered by the sensor, even if the power source is
disconnected. To get back to the self adjustment mode, use the
ADJ
button only.
ENTRANCE TO THE SELF ADJUSTMENT MODE:
Check that no objects
are in front of the sensor. Press the
ADJ
button. Once a quick flashing
of the red light of the sensor eye is perceived, remove your hand
holding the remote control and move away from the sensor area. The
ideal sensor range for the specific location will be set automatically.
Once the self adjustment has taken place, the solenoid valve will be
opened and closed for 1 second as an indication that the ideal sensor
range was set and the product is ready for use.
SECURITY TIME:
The Security time, prevents continuous running
of water due to reflections or vandalism. By default, if the sensor
is covered for more than 90 seconds the water flow will shut
automatically. To resume regular operation any obstruction must be
removed.
Press the
SEC
button. Wait until a quick flashing of the red light in the
sensor eye is perceived. Then, press
+
to increase the security time
and
–
to reduce it.
DELAY IN TIME
: It is recommended to change the delay in time for
flush valves for urinals or toilets only. If required, the delay in time can
also be modified in faucets as follows:
Press the IN button. Wait until a quick flashing of the red light in the
sensor eye is perceived. Then, press + to increase the delay in time
and – to reduce it.