Sterling Power Products SIB121000 Instructions Manual Download Page 4

S

te

rl

in

g

 P

o

w

e

P

ro

d

u

c

ts

C

o

p

y

ri

g

h

AC cable chart

                      

Conductor size    Current         ½ for 110V 

1.0   mm2                10                  2400 watts
1.25 mm2                13                  3120 watts
1.5   mm2                15                  3600 watts
2.5   mm2                20                  4800 watts
4.0   mm2                25                  6000 watts

Max power (230V)

Amps   AWG     mm dia    m

 400    0000         11.6        106
 320      000         10.4          85
 285        00           9.2          66
 250          0           8.2          52
 200          1           7.3          42        
 180          2           6.5          34
 150          3           5.8          27
 135          4           5.2          21
 120          5           4.6          16
 100          6           4.1          13
   90          7           3.6          10
   70          8           3.3            8
   60          9           2.9            6
   50        10           2.5            5

m2

DC cables sizes, there is no fixed

simple chart for this as length of cable 

run is a large part of the calculation.

I would work on every 3 meter / 10 ft then x 2

 the thickness. 

By far the best advice is to keep DC runs as 

short as possible 

                                In Line DC fuse           
  Fuse Recommended use Sterling ANL fuse & holder  
   

300 watt   600 watt   1000 watt    1600 watt  2000 watt

   

12V

12V

12V

12V

12V

24V

24V

 24V

24V

12V

 60A     

 100A    

 150A      

 250A    

 350A   

   

 30A     

   50A   

 70A        

 125A    

 180A   

and electric grinders etc. This could require a 500-1000% power increase 

terminal and the black cable to the negative terminal of the battery. 

above the product rating i.e. a 80W fridge may require 800W to fire it up (a 

Reverse polarity could destroy the unit and would not be under warranty. 

fridge is probably the hardest product to operate). 

7) In the event of this unit being installed into a ring main or 
extension power circuit The output voltage of this unit must never be 
on your AC system at the same time as the 230V external mains line.

 

If the output voltage is to be used on a ring mains system, a suitable two-
pole crossover switch must be used. failure to do this will result in the 
destruction of this unit even if switched off that the time and not covered 
under warranty.
8) Only use products that are within the ability of the inverter to operate 
them. Also, take into account overload requirements on things like fridge 
motor and electric grinders etc. This could require a 500-1000% power 
increase above the product rating, I.e. a 80W fridge may require 800W to 
fire it up (a fridge is probably the hardest product to operate). 
9) 

1) Fit in a cool dry well ventilated space as close to the battery bank as 
possible. Ensure that the inverter has the correct voltage for your boat or 
vehicle.
2) Ensure at least 2 of the 5 mounting supports are screwed to the 

Remove all AC power 

bulkhead.

products from the output of the inverter. Switch the local on/off switch on 

3) Where cable is not supplied (1000-2000 units) or cable requires 

the main inverter to the off position. Ensure the remote control switch is in 

extending ensure the cable is large enough to deal with the cable runs.

the off position. Insert the remote control unit into the remote socket on the 

4) Install DC cable fuse into each installation fuse size per unit in 

front of the inverter. The switch on the remote control is now the one in 

specification. 

charge ( keep the local control switch off ). switch the unit on and off using 

5) Secure the unit in position, fit fuse and isolation switch as required in 

the remote.  

position, as per Fig 5.
6) 

Do not reverse the DC cables!

 Connect the red cable to the positive 

Remote control operation:

 Remove all AC power products from the 

output of the inverter. Switch the local on/off switch on the main inverter to 
the off position. Ensure the remote control switch is in the off position. 
Insert the remote control unit into the remote socket on the front of the 
inverter. The switch on the remote control is now the one in charge ( keep 
the local control switch off ).  

Installation for option 2 RCD version

This is a more dangerous product to install due to the 230V flying lead and 
should be installed by a professional electrical engineer. 

Make sure the 

product is switched off and the RCD is also switched off. Ensure the 
naked AC fly lead is connected first before the DC. If the DC is 
connected this lead will become live if not switched off, this is high 
voltage AC and could kill. 

This unit comes standard as centre tapped, and must be converter to 
neutral earth bonding before installation 

Ensure the Neutral bonding 

link is connected ( small fuse ) in position 11 in fig 1 ( same position on Fig 
2, remove the cover and insert the  small fuse in that link, the unit is 
supplied  without that link inserted. by inserting the link the unit becomes 
neutral earth bonded, essential for the operation of the RCD 

Remote control installation and operation:

 

Your 100 % satisfaction is our goal.

 We realise that every customer 

our company and does not apply for shipping organised by yourself. 

and circumstance is unique. If you have a problem, question, or 

Please do not throw out any shipping or packaging materials.

comment please do not hesitate to contact us. We welcome you to 
contact us even after the warranty and return time has passed.

All returns for any reason will require a proof of purchase with the 
purchase date. The proof of purchase must be sent with the returned 

Product Warranty:

shipment. If you have no proof of purchase call the vendor who 

Each product manufactured by Sterling Power comes with at least a 2 

supplied you and acquire the appropriate 

documentation. 

year limited factory warranty. Certain Products have a warranty period of 

To make a claim under warranty, call our customer care check telephone 

time greater than 2 years. Each product is guaranteed against defects in 
material or workmanship from the date of purchase. At our discretion, we 

numbers on 

www.sterling-power.com

 or 

will repair or replace free of charge any defects in material or 

www.sterling-power-usa.com

We will make the best 

workmanship that fall within the warranty period of the Sterling Power 

effort to repair or replace the product, if found to be defective within the 

product. The following conditions do apply:

terms of the warranty. Sterling Power will ship the repaired or warranty 

 

replacement product back to the purchaser, if purchased from us.

-  The original receipt or proof of purchase must be submitted to 
claim warranty. If proof cannot be located a warranty is calculated 

Please review the documentation included with your purchase. Our 

from the date of manufacture.

warranty only covers orders purchased from Sterling Power. We 

- Our warranty covers manufacture and material defects. Damages 

cannot accept warranty claims from any other Sterling Power 

caused by abuse, neglect, accident, alterations and improper use 

distributor. Purchase or other acceptance of the product shall be on the 

are not covered under our warranty. 

condition and agreement that Sterling Power USA LLC and Sterling 

- Warranty is null and void if damage occurs due to negligent 

Power LTD shall not be liable for incidental or consequential damages 

repairs. 

of any kind. Some states may not allow the exclusion or limitation of 

- Customer is responsible for inbound shipping costs of the 

consequential damages, so, the above limitations may not apply to 

product to Sterling Power either in the USA or England. 

you. Additionally, Sterling Power USA and Sterling Power LTD neither 

- Sterling Power will ship the repaired or warranty replacement 

assumes nor authorizes any person for any obligation or liability in 

product back to the purchaser at their cost. 

connection with the sale of this product. This warranty is made in lieu 
of all other obligations or liabilities. This warranty provides you specific 

If your order was damaged in transit or arrives with an error, please 

legal rights and you may also have other rights, which vary from state 

contact us ASAP so we may take care of the matter promptly and at no 

to state. This warranty is in lieu of all other, expressed or implied. 

expense to you. This only applies for shipping which was undertaken by 

Customer Service & Warranty

12 v unit alarms and trips for 24 v x 2 

High V trip = 15-16V

Low V alarm = 10.2-10.8V

Low V trip= 9.2-9.8V

230 V AC

50 Hz

Summary of Contents for SIB121000

Page 1: ...watt Twin sockets interchangeable between both Optional extra 4 1 kg 190x85x300L 8 mm connection SIB242000 12V 1000 watt with RCD Optional extra 3 5 kg 190x85x330L 8 mm connection SIBR121000 12V 1600 watt with RCD Optional extra 3 6 kg 190x85x330L 8 mm connection SIBR121600 12V 2000 watt with RCD Optional extra 4 1 kg 190x85x330L 8 mm connection SIBR122000 24V 1000 watt with RCD Optional extra 3 5...

Page 2: ...top when voltage increase Warning Low input trip Green on red on Yes No Charge batteries then switch unit off and on to restart High input voltage Green on red on No No Reduce input voltage then switch off and on again to reset Overload Shutdown Green on red on No No Reduce load switch off and on to restart Over Temp shut Green on red on Yes No Unit must return to temp then switch off and on to re...

Page 3: ...ion switch Option 2 Type with Pre wired RCD 230V AC earth to vehicle chassis or boat bonding system Live Earth Neutral Fig 3 Fig 6 Fig 5 Fig 4 Optional remote control with 10m cable Optional remote control with 10m cable RCD Residual earth detector Breaker earth leak detector Pre fitted RCD Installation for Option 1 twin socket product All electrical installations should be carried out by a profes...

Page 4: ... connected this lead will become live if not switched off this is high voltage AC and could kill This unit comes standard as centre tapped and must be converter to neutral earth bonding before installation Ensure the Neutral bonding link is connected small fuse in position 11 in fig 1 same position on Fig 2 remove the cover and insert the small fuse in that link the unit is supplied without that l...

Page 5: ...att Deux prises interchangeable entre les deux Option 2 0 kg 190x85x300L 1m DC 8 mm ring SW241000 24V 1600 watt Deux prises interchangeable entre les deux Option 3 6 kg 190x85x360L 8 mm connection SW241600 24V 2000 watt Deux prises interchangeable entre les deux Option 4 1 kg 190x85x400L 8 mm connection SW242000 12V 1000 watt avec DDR Option 2 0 kg 190x85x300L 1m DC 8 mm ring SWR121000 12V 1600 wa...

Page 6: ...rée Verte on rouge on oui non Charger la batterie puis éteindre trop basse et rallumer l appareil Tension entrée haute Verte on rouge on Non Non Réduire la tension entrée éteindre l appareil et le rallumer Coupure surcharge Verte on rouge on Non Non Réduire la charge éteindre et rallumer pour redémarrer Coupure température Verte on rouge on oui Non L appareil doit revenir à une température haute n...

Page 7: ...fusible Sterling GANL muni du fusible correct GANL voir spécifications Batterie _ Interrupteur isolant Sterling Option 2 Système DDR précâblé 230V CC Terre vers le chassis du véhicule ou la ligne de terre du bateau Phase Terre Neutre Fig 3 Fig 6 Fig 5 Fig 4 Ecran de contrôle en option avec 10m câble Ecran de contrôle en option avec 10m câble DDR Disjoncteur différentiel Résiduel détecteur fuite à ...

Page 8: ...e le convertisseur a une appareils utilisant le courant alternatifs du convertisseur Mettez tension adaptée à votre bateau ou à votre véhicule l interrupteur du convertisseur sur off Assurez vous que l interrupteur de 2 Assurez vous qu au moins 2 des 5 supports sont vissés sur la cloison l écran de contrôle est sur off Branchez alors l écran de contrôle à 3 Quand les câbles ne sont pas fournis App...

Page 9: ... wechselbar optional 3 6 kg 190x85x300L 8mm Anschlussbolzen SIB241600 24V 2000W UK Deutsche Steckdose wechselbar optional 4 1 kg 190x85x300L 8mm Anschlussbolzen SIB242000 12V 1000 W mit 30mA FI Schutzschalter optional 3 5 kg 190x85x330L 8mm Anschlussbolzen SIBR121000 12V 1600 W mit 30mA FI Schutzschalter optional 3 6 kg 190x85x330L 8mm Anschlussbolzen SIBR121600 12V 2000 W mit 30mA FI Schutzschalt...

Page 10: ...t Warnung Unterspannungs grün rot Ein Aus Batterien laden und Gerät a Überspannungs Aus Aus Spannung reduzieren und Gerät Überlastabschaltung Aus Aus Leistungsabnahme reduzieren und Gerät Übertemperatur abschaltung us und wieder einschalten grün rot abschaltung aus und wieder einschalten grün rot aus und wieder einschalten grün rot Ein Aus Gerät abkühlen lassen und anschließend aus und wieder eins...

Page 11: ...ine Elektrofachmann ausgeführt werden Sollten irgendwelche Zweifel bestehen bitten wir um sofortige Kontaktaufnahme Installieren Sie dieses Produkt nicht wenn Sie nicht über die fachliche Qualifikation verfügen Hohe Spannungen sind lebensgefährlich 6 Befestigen Sie das Gerät installieren Sie die Sicherungen und Schalter 7 1 Montieren Sie das Gerät an einem trockenen kühlen und gut belüfteten Ort A...

Page 12: ... wird über die Sicherung pos 11 fig 1 auf der Rückseite des Gerätes gemacht Dieses befindet sich unter dem Negativ Anschluss Öffnen sie die Schutzabdeckung und stecken Sie die beiliegende Sicherung in die Öffnung Anschließend verschließen Sie die Sicherung mit der Kappe Anschließend funktionert ein FI Mstellen Sie sicher dass das Gerät ausgeschaltet ist und auch der Customer Service Warranty Ihre ...

Reviews: