Conductor size Current ½ for 110V
1.0 mm2 10 2400 watts
1.25 mm2 13 3120 watts
1.5 mm2 15 3600 watts
2.5 mm2 20 4800 watts
4.0 mm2 25 6000 watts
Max power (230V)
Amps AWG mm dia m
400 0000 11.6 106
320 000 10.4 85
285 00 9.2 66
250 0 8.2 52
200 1 7.3 42
180 2 6.5 34
150 3 5.8 27
135 4 5.2 21
120 5 4.6 16
100 6 4.1 13
90 7 3.6 10
70 8 3.3 8
60 9 2.9 6
50 10 2.5 5
m2
DC cables sizes, there is no fixed
simple chart for this as length of cable
run is a large part of the calculation.
I would work on every 3 meter / 10 ft then x 2
the thickness.
By far the best advice is to keep DC runs as
short as possible
In Line DC fuse
Fuse Recommended use Sterling ANL fuse & holder
300 watt 600 watt 1000 watt 1600 watt 2000 watt
12V
12V
12V
12V
12V
24V
24V
24V
24V
12V
60A
100A
150A
250A
350A
30A
50A
70A
125A
180A
and electric grinders etc. This could require a 500-1000% power increase
terminal and the black cable to the negative terminal of the battery.
above the product rating i.e. a 80W fridge may require 800W to fire it up (a
Reverse polarity could destroy the unit and would not be under warranty.
fridge is probably the hardest product to operate).
7) In the event of this unit being installed into a ring main or
extension power circuit The output voltage of this unit must never be
on your AC system at the same time as the 230V external mains line.
If the output voltage is to be used on a ring mains system, a suitable two-
pole crossover switch must be used. failure to do this will result in the
destruction of this unit even if switched off that the time and not covered
under warranty.
8) Only use products that are within the ability of the inverter to operate
them. Also, take into account overload requirements on things like fridge
motor and electric grinders etc. This could require a 500-1000% power
increase above the product rating, I.e. a 80W fridge may require 800W to
fire it up (a fridge is probably the hardest product to operate).
9)
1) Fit in a cool dry well ventilated space as close to the battery bank as
possible. Ensure that the inverter has the correct voltage for your boat or
vehicle.
2) Ensure at least 2 of the 5 mounting supports are screwed to the
Remove all AC power
bulkhead.
products from the output of the inverter. Switch the local on/off switch on
3) Where cable is not supplied (1000-2000 units) or cable requires
the main inverter to the off position. Ensure the remote control switch is in
extending ensure the cable is large enough to deal with the cable runs.
the off position. Insert the remote control unit into the remote socket on the
4) Install DC cable fuse into each installation fuse size per unit in
front of the inverter. The switch on the remote control is now the one in
specification.
charge ( keep the local control switch off ). switch the unit on and off using
5) Secure the unit in position, fit fuse and isolation switch as required in
the remote.
position, as per Fig 5.
6)
Do not reverse the DC cables!
Connect the red cable to the positive
Remote control operation:
Remove all AC power products from the
output of the inverter. Switch the local on/off switch on the main inverter to
the off position. Ensure the remote control switch is in the off position.
Insert the remote control unit into the remote socket on the front of the
inverter. The switch on the remote control is now the one in charge ( keep
the local control switch off ).
Installation for option 2 RCD version
This is a more dangerous product to install due to the 230V flying lead and
should be installed by a professional electrical engineer.
Make sure the
product is switched off and the RCD is also switched off. Ensure the
naked AC fly lead is connected first before the DC. If the DC is
connected this lead will become live if not switched off, this is high
voltage AC and could kill.
This unit comes standard as centre tapped, and must be converter to
neutral earth bonding before installation
Ensure the Neutral bonding
link is connected ( small fuse ) in position 11 in fig 1 ( same position on Fig
2, remove the cover and insert the small fuse in that link, the unit is
supplied without that link inserted. by inserting the link the unit becomes
neutral earth bonded, essential for the operation of the RCD
Remote control installation and operation:
Your 100 % satisfaction is our goal.
We realise that every customer
our company and does not apply for shipping organised by yourself.
and circumstance is unique. If you have a problem, question, or
Please do not throw out any shipping or packaging materials.
comment please do not hesitate to contact us. We welcome you to
contact us even after the warranty and return time has passed.
All returns for any reason will require a proof of purchase with the
purchase date. The proof of purchase must be sent with the returned
Product Warranty:
shipment. If you have no proof of purchase call the vendor who
Each product manufactured by Sterling Power comes with at least a 2
supplied you and acquire the appropriate
documentation.
year limited factory warranty. Certain Products have a warranty period of
To make a claim under warranty, call our customer care check telephone
time greater than 2 years. Each product is guaranteed against defects in
material or workmanship from the date of purchase. At our discretion, we
numbers on
www.sterling-power.com
or
will repair or replace free of charge any defects in material or
www.sterling-power-usa.com
.
We will make the best
workmanship that fall within the warranty period of the Sterling Power
effort to repair or replace the product, if found to be defective within the
product. The following conditions do apply:
terms of the warranty. Sterling Power will ship the repaired or warranty
replacement product back to the purchaser, if purchased from us.
- The original receipt or proof of purchase must be submitted to
claim warranty. If proof cannot be located a warranty is calculated
Please review the documentation included with your purchase. Our
from the date of manufacture.
warranty only covers orders purchased from Sterling Power. We
- Our warranty covers manufacture and material defects. Damages
cannot accept warranty claims from any other Sterling Power
caused by abuse, neglect, accident, alterations and improper use
distributor. Purchase or other acceptance of the product shall be on the
are not covered under our warranty.
condition and agreement that Sterling Power USA LLC and Sterling
- Warranty is null and void if damage occurs due to negligent
Power LTD shall not be liable for incidental or consequential damages
repairs.
of any kind. Some states may not allow the exclusion or limitation of
- Customer is responsible for inbound shipping costs of the
consequential damages, so, the above limitations may not apply to
product to Sterling Power either in the USA or England.
you. Additionally, Sterling Power USA and Sterling Power LTD neither
- Sterling Power will ship the repaired or warranty replacement
assumes nor authorizes any person for any obligation or liability in
product back to the purchaser at their cost.
connection with the sale of this product. This warranty is made in lieu
of all other obligations or liabilities. This warranty provides you specific
If your order was damaged in transit or arrives with an error, please
legal rights and you may also have other rights, which vary from state
contact us ASAP so we may take care of the matter promptly and at no
to state. This warranty is in lieu of all other, expressed or implied.
expense to you. This only applies for shipping which was undertaken by
Customer Service & Warranty
12 v unit alarms and trips for 24 v x 2
High V trip = 15-16V
Low V alarm = 10.2-10.8V
Low V trip= 9.2-9.8V
230 V AC