Option 1

Twin socket

adjustable between 

Centre tapped earth

and Neutral earth bonding 

Option 2

    

 Model                      Centre tapped Earth     Neutral earth bonded      Remote        Weight      Size mm                 Cables             Part number

12V 300 watt Twin sockets               interchangeable between both                 Optional extra     1.4 kg    190x85x210L     1m DC 8 mm ring        SIB12300
12V 600 watt Twin sockets               interchangeable between both                 Optional extra     2.2 kg    190x85x250L     1m DC 8 mm ring        SIB12600
12V 1000 watt Twin sockets             interchangeable between both                 Optional extra     3.5 kg    190x85x300L     8 mm connection        SIB121000
12V 1600 watt Twin sockets             interchangeable between both                 Optional extra     3.6 kg    190x85x300L     8 mm connection        SIB121600
12V 2000 watt Twin sockets             interchangeable between both                 Optional extra     4.1 kg    190x85x300L     8 mm connection        SIB122000

24V 300 watt Twin sockets               interchangeable between both                 Optional extra     1.4 kg    190x85x210L     1m DC 8 mm ring        SIB24300
24V 600 watt Twin sockets               interchangeable between both                 Optional extra     2.2 kg    190x85x250L     1m DC 8 mm ring        SIB24600
24V 1000 watt Twin sockets             interchangeable between both                 Optional extra     3.5 kg    190x85x300L     8 mm connection        SIB241000
24V 1600 watt Twin sockets             interchangeable between both                 Optional extra     3.6 kg    190x85x300L     8 mm connection        SIB241600
24V 2000 watt Twin sockets             interchangeable between both                 Optional extra     4.1 kg    190x85x300L     8 mm connection        SIB242000

12V 1000 watt with RCD                                

  Optional extra     3.5 kg    190x85x330L     8 mm connection        SIBR121000

12V 1600 watt with RCD                                

  Optional extra     3.6 kg    190x85x330L     8 mm connection        SIBR121600

12V 2000 watt with RCD                                

  Optional extra     4.1 kg    190x85x330L     8 mm connection        SIBR122000

24V 1000 watt with RCD                                

  Optional extra     3.5 kg    190x85x330L     8 mm connection        SIBR241000

24V 1600 watt with RCD                               

   Optional extra     3.6 kg    190x85x330L     8 mm connection        SIBR241600

24V 2000 watt with RCD                               

   Optional extra     4.1 kg    190x85x330L     8 mm connection        SIBR242000

Remote control ( 

fits all the above models

 )                                                                                              90 x 60 x 20           10 meter                SWR

interchangeable between both 
interchangeable between both 
interchangeable between both 

interchangeable between both 

 interchangeable between both
 interchangeable between both

Pre-fitted

and wired

RCD option

with 1 meter

 AC cable

Optional

remote control

with 10 meter

cable

Pure Sine Wave Inverters

Pro 

Power SB (R) 

12V / 24V DC >> 230V AC
 & 110V AC

technology

4

 

D

 :

U

L

R

A

A

T

I

B

G

I

L

E

D :

 

 

: D

CI

E

M

S

A

IG

N

N

Y

D

ProDigital 

RoHS

compliant

Sterling Power Products Ltd.

www.sterling-power.com

www.sterling-power-usa.com

Sterling Power Products 

Pure

sine wave

output

RoHS

compliant

English

French

Deutsch

EN60950-1
EN55022: A2:2003 CLASS B
EN55024:2003
EN61000-3-2:2000
EN61000-3-3:1995/A1:2001
IEC61000-4-2:A2:2003
IEC61000-4-3:20002/A1:2002
IEC61000-4-4:2004
IEC61000-4-6:A1:2004
IEC61000-4-8:A1:2000

Pre wired RCD

adjustable between 

Centre tapped earth

and Neutral earth bonding

Summary of Contents for SIB121000

Page 1: ...watt Twin sockets interchangeable between both Optional extra 4 1 kg 190x85x300L 8 mm connection SIB242000 12V 1000 watt with RCD Optional extra 3 5 kg 190x85x330L 8 mm connection SIBR121000 12V 1600 watt with RCD Optional extra 3 6 kg 190x85x330L 8 mm connection SIBR121600 12V 2000 watt with RCD Optional extra 4 1 kg 190x85x330L 8 mm connection SIBR122000 24V 1000 watt with RCD Optional extra 3 5...

Page 2: ...top when voltage increase Warning Low input trip Green on red on Yes No Charge batteries then switch unit off and on to restart High input voltage Green on red on No No Reduce input voltage then switch off and on again to reset Overload Shutdown Green on red on No No Reduce load switch off and on to restart Over Temp shut Green on red on Yes No Unit must return to temp then switch off and on to re...

Page 3: ...ion switch Option 2 Type with Pre wired RCD 230V AC earth to vehicle chassis or boat bonding system Live Earth Neutral Fig 3 Fig 6 Fig 5 Fig 4 Optional remote control with 10m cable Optional remote control with 10m cable RCD Residual earth detector Breaker earth leak detector Pre fitted RCD Installation for Option 1 twin socket product All electrical installations should be carried out by a profes...

Page 4: ... connected this lead will become live if not switched off this is high voltage AC and could kill This unit comes standard as centre tapped and must be converter to neutral earth bonding before installation Ensure the Neutral bonding link is connected small fuse in position 11 in fig 1 same position on Fig 2 remove the cover and insert the small fuse in that link the unit is supplied without that l...

Page 5: ...att Deux prises interchangeable entre les deux Option 2 0 kg 190x85x300L 1m DC 8 mm ring SW241000 24V 1600 watt Deux prises interchangeable entre les deux Option 3 6 kg 190x85x360L 8 mm connection SW241600 24V 2000 watt Deux prises interchangeable entre les deux Option 4 1 kg 190x85x400L 8 mm connection SW242000 12V 1000 watt avec DDR Option 2 0 kg 190x85x300L 1m DC 8 mm ring SWR121000 12V 1600 wa...

Page 6: ...rée Verte on rouge on oui non Charger la batterie puis éteindre trop basse et rallumer l appareil Tension entrée haute Verte on rouge on Non Non Réduire la tension entrée éteindre l appareil et le rallumer Coupure surcharge Verte on rouge on Non Non Réduire la charge éteindre et rallumer pour redémarrer Coupure température Verte on rouge on oui Non L appareil doit revenir à une température haute n...

Page 7: ...fusible Sterling GANL muni du fusible correct GANL voir spécifications Batterie _ Interrupteur isolant Sterling Option 2 Système DDR précâblé 230V CC Terre vers le chassis du véhicule ou la ligne de terre du bateau Phase Terre Neutre Fig 3 Fig 6 Fig 5 Fig 4 Ecran de contrôle en option avec 10m câble Ecran de contrôle en option avec 10m câble DDR Disjoncteur différentiel Résiduel détecteur fuite à ...

Page 8: ...e le convertisseur a une appareils utilisant le courant alternatifs du convertisseur Mettez tension adaptée à votre bateau ou à votre véhicule l interrupteur du convertisseur sur off Assurez vous que l interrupteur de 2 Assurez vous qu au moins 2 des 5 supports sont vissés sur la cloison l écran de contrôle est sur off Branchez alors l écran de contrôle à 3 Quand les câbles ne sont pas fournis App...

Page 9: ... wechselbar optional 3 6 kg 190x85x300L 8mm Anschlussbolzen SIB241600 24V 2000W UK Deutsche Steckdose wechselbar optional 4 1 kg 190x85x300L 8mm Anschlussbolzen SIB242000 12V 1000 W mit 30mA FI Schutzschalter optional 3 5 kg 190x85x330L 8mm Anschlussbolzen SIBR121000 12V 1600 W mit 30mA FI Schutzschalter optional 3 6 kg 190x85x330L 8mm Anschlussbolzen SIBR121600 12V 2000 W mit 30mA FI Schutzschalt...

Page 10: ...t Warnung Unterspannungs grün rot Ein Aus Batterien laden und Gerät a Überspannungs Aus Aus Spannung reduzieren und Gerät Überlastabschaltung Aus Aus Leistungsabnahme reduzieren und Gerät Übertemperatur abschaltung us und wieder einschalten grün rot abschaltung aus und wieder einschalten grün rot aus und wieder einschalten grün rot Ein Aus Gerät abkühlen lassen und anschließend aus und wieder eins...

Page 11: ...ine Elektrofachmann ausgeführt werden Sollten irgendwelche Zweifel bestehen bitten wir um sofortige Kontaktaufnahme Installieren Sie dieses Produkt nicht wenn Sie nicht über die fachliche Qualifikation verfügen Hohe Spannungen sind lebensgefährlich 6 Befestigen Sie das Gerät installieren Sie die Sicherungen und Schalter 7 1 Montieren Sie das Gerät an einem trockenen kühlen und gut belüfteten Ort A...

Page 12: ... wird über die Sicherung pos 11 fig 1 auf der Rückseite des Gerätes gemacht Dieses befindet sich unter dem Negativ Anschluss Öffnen sie die Schutzabdeckung und stecken Sie die beiliegende Sicherung in die Öffnung Anschließend verschließen Sie die Sicherung mit der Kappe Anschließend funktionert ein FI Mstellen Sie sicher dass das Gerät ausgeschaltet ist und auch der Customer Service Warranty Ihre ...