MANUAL OPERATION IN CASE OF POWER FAILURE
RISK OF INJURY
DISCONNECT OR TURN OFF ALL POWER SUPPLY BEFORE STARTING
INTERVENTION ON THE COVANA OPERATOR
WARNING
1. Disconnect or turn off the power
2. Unscrew and remove the four screws on the cover of the operator.
3. Remove the operator
4. Use a ½" or 13mm hexagon socket wrench to operate the operator by turning the input
shaft
SLOWLY TURN THE SHAFT - STOP IF EXCESS TENSION IS FELT
NEVER USE A POWER TOOL AS THIS WILL DAMAGE UNIT
5. Turn the input shaft clockwise to lower the roof and counterclockwise to raise the roof
6. Put the cover back on the operator
7. Reconnect or turn on power