LIMIT SWITCH ADJUSTMENT
Note:
The UP & DOWN limits are factory adjusted and there is no need for re-adjustment.
If adjustments are required to ensure the Covana roof does not come into contact with its
surroundings, while elevating, the UP direction may be decreased. Never change the
factory settings of the DOWN limits or increase the UP limit, failing to do so may result in
possible equipment damage and/or injury:
1.
Remove the retaining screw and slide the camplate from operator frame.
2.
To reduce the travel to UP direction, turn the UP cam counterclockwise as per arrow
3.
Once the cam is set to the desired position, reinstall the camplate and make sure that
it is properly inserted in the slot of each cam.
NEVER OPERATE THE SYSTEM WITH
THE CAMPLATE REMOVED.
4.
Replace the retaining screw to prevent the camplate from coming out.
5.
Reinstall the operator, turn the power ON and test the system.
RISK OF INJURY
DISCONNECT OR TURN OFF ALL POWER SUPPLY BEFORE STARTING
ANY INTERVENTION ON THE SPA GAZEBO
WARNING
KEY OPERATING INSTRUCTIONS
Turn the key to the right — clockwise to raise the roof
Turn the key to the left — counterclockwise to lower the roof
Key will automatically return to center, off position, when released
Camplate and retaining screw
Summary of Contents for COVANA
Page 2: ...202558 COVANA III Revision 5 2 La version française du manuel débute à la page 21 FRANÇAIS ...
Page 8: ...202558 COVANA III Revision 5 8 FRAME DIMENSIONS AND FOOTPRINT ...
Page 12: ...202558 COVANA III Revision 5 12 Wiring Schematic Diagram 120VAC 60Hz Operator North America ...
Page 13: ...202558 COVANA III Revision 5 13 Wiring Schematic Diagram 220VAC 50Hz Operator Europe Only ...