4. INSTALL ROUND DUCTWORK

   Connect the round ductwork (not included) to the damper/duct connector, and run the 

   ductwork to a roof or wall cap (not included). Using tape (not included), secure all the 

   ductwork connections so that they are air tight.

ASSEMBLY INSTRUCTIONS

CONNECT ELECTRICAL WIRING

INSTALL GRILLE

3

Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the 

wiring plate. Refer to the wiring diagram, and connect the wires as shown.

The ducting from this fan to the outside of building has a strong effect on the air flow, 

noise and energy use of the fan. Use the shortest, straightest duct routing possible for 

best performance, and avoid installing the fan with smaller ducts than recommended. 

Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans 

installed with existing ducts may not achieve their rated air flow.

UNIT

BLACK (BLK)

NIGHT

LIGHT

LIGHT

SWITCH BOX

FAN

120V AC LINE IN

GROUND (GRD)

RED

WHITE (WHT)

BLUE (BLU)

FAN 

RECEPTACLE

LIGHT

RECEPTACLE

WIRE 

PANEL

Insert the light plug from the grille assembly into the wire panel.Pinch the 

grille springs on the sides of the grille, and position the grille into the 

housing with the grille springs in the appropriate slots. Push the grille 

assembly towards the ceiling to secure.

Remove the lens

Carefully pry out the light lens by inserting a small,flathead screwdriver 

between the grille and lens.

Install the light bulbs

Install a 26W max. fluorescent bulb and a 4W incandescent night light 

bulb. Replace the lens.

Wire panel

Summary of Contents for SE80TL

Page 1: ...ciety for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities e When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities f Ducted fans must always be vented to the outdoors g Acceptable for use over a tub or shower when connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit ceiling install...

Page 2: ... hole and secure the hanger bars together using flange screws 3 ATTACH DAMPER DUCT CONNECTOR Snap the damper duct connector onto the fan housing The connector must be flush with the top of the housing and the damper flap should fall closed Insulated flexible duct is recommended for the quietest possible installation If rigid duct is used a short 1 3 feet section of insulated flexible duct will ens...

Page 3: ...or best performance and avoid installing the fan with smaller ducts than recommended Insulation around the ducts can reduce energy loss and inhibit mold growth Fans installed with existing ducts may not achieve their rated air flow UNIT BLACK BLK NIGHT LIGHT LIGHT SWITCH BOX FAN 120V AC LINE IN GROUND GRD RED WHITE WHT BLUE BLU FAN RECEPTACLE LIGHT RECEPTACLE WIRE PANEL Insert the light plug from ...

Page 4: ...ING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies This warranty does not cover incidental or consequential damages Some states do not allow the exclusion of incidental or consequential damages so this limitation may not apply to you Some states do not allow limitations on how lon...

Reviews: