background image

WARNING

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

CAUTION

CLEANING & MAINTENANCE

OPERATION

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit

with the dusting brush attachment.The motor is permanently lubricated and never needs oiling. If the motor bearings are 

making excessive or unusual noises, replace the motor with the exact service motor. The impeller should also be replaced.

1

EXHAUST FAN

SE110L

SE80TL

a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent 

     power from being switching on accidentally. When the service disconnecting means cannot be locked, securely fasten 

     a prominent warning device, such as a tag, to the service panel. 

c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and 

     standards, including fire-rated construction codes and standards. 

d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equip-

     ment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those 

     published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and 

     Air Conditioning   Engineers (ASHRAE), and the local code authorities. 

e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 

f ). Ducted fans must always be vented to the outdoors. 

g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch 

     circuit (ceiling installation only). 

h).This unit must be grounded. 

 i). Not for Use in Kitchens.

 j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within 

     walls or ceilings or into attics, crawl spaces, or garages.

 k).WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control 

     Device.

 l). The fan must not be installed in a ceiling thermally insulated to a value greater R40.

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 

2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. 

    DO NOT MOUNT THIS PRODUCT IN A WALL. 

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off 

power unit. 

4. Please read specification label on product for further information and requirements. 

   *The manual in electronic format can be download in our company web, or obtained from our dealer.

WARNING -TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING:

The fan, light, and night light can be operated separately. Use a 3-function wall control. See “Connect Wiring” for details.

Summary of Contents for SE80TL

Page 1: ...ciety for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities e When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities f Ducted fans must always be vented to the outdoors g Acceptable for use over a tub or shower when connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit ceiling install...

Page 2: ... hole and secure the hanger bars together using flange screws 3 ATTACH DAMPER DUCT CONNECTOR Snap the damper duct connector onto the fan housing The connector must be flush with the top of the housing and the damper flap should fall closed Insulated flexible duct is recommended for the quietest possible installation If rigid duct is used a short 1 3 feet section of insulated flexible duct will ens...

Page 3: ...or best performance and avoid installing the fan with smaller ducts than recommended Insulation around the ducts can reduce energy loss and inhibit mold growth Fans installed with existing ducts may not achieve their rated air flow UNIT BLACK BLK NIGHT LIGHT LIGHT SWITCH BOX FAN 120V AC LINE IN GROUND GRD RED WHITE WHT BLUE BLU FAN RECEPTACLE LIGHT RECEPTACLE WIRE PANEL Insert the light plug from ...

Page 4: ...ING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies This warranty does not cover incidental or consequential damages Some states do not allow the exclusion of incidental or consequential damages so this limitation may not apply to you Some states do not allow limitations on how lon...

Reviews: